Page 36 from 43
6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
Settings parameters
Go to
Installer Level
Technician Level
Connectivity
WIFI module to be launched
(compatible for all MPP 2)
______
(Note: from 0 to 60
sec)
The value defined here is defined in
seconds and will create a delay in the
startup sequence in order to allow
pre-heated water to reach appliance
without unnecessary burner
activation when water is hot.
ºC (default)
ºF (possible
selection)
To set one of these units it is
necessary to store the value. For
that, press program button until the
desired option flashes on the display
On / Off
Backlight Control
Table 17 – Settings parameters for special features
The access to the data visualization mode, is made by entering first in the “service mode”
and then, scrolling to the parameter “P4” of the adjustment mode.
Diagnostic mode and
visualization mode
Installer Level
Technician Level
Comments
This mode helps
the installer in the
startup to check
parameters such
as water flow
through the
appliance and inlet
/ outlet
temperatures
This mode helps
the technician to
find some
information useful
to adjust and to
check functionality
of the appliance.
Main
recommendation is to
perform always a
check on the last 10
failures in memory in
order to analyze
eventual problems in
installation that might
need to be corrected
Table 18 – P4
By pressing the “P” button while the display shows “P4”, the LCD will enter into
visualization mode and will show “E”, meaning “Exit” from the visualization mode. By
pressing “P” button again, the LCD will show “P4”, i.e. the visualization mode has been
exited.
After entering into data visualization mode (showing “E”) and then pressing “+” or “-”
button, the parameter and failure visualization fields can be selected as shown in table 5.