7.2
Controller / module
Customer complaint
Cause
Remedial action
Running time too long
Component is not actuated
Scorched connections
Alternating rinse technology, energy saving
Triac on the module
does not switch properly, smoke traces
may be visible on the module
Mains plug
Advise customer,
See Consumption rates
or
Alternate
rinsing technology
Before replacing the module, always measure
the connected consumers (valves, actuators, etc.).
Comply with safety instructions
The plug repair set (mat.: 480937) can be used for
defective connections on electronic controllers.
58300000002393_ara_en_a.doc – 31.07.07
Seite 44 von 60