Installation and connection
34
Drinking water connection
1.
Fasten the drinking water connection
to the tap according
to the installation instructions using
the enclosed parts.
Ensure that the drinking water
connection is not kinked, crushed
or twisted.
2.
When replacing the appliance,
always use a new water supply hose.
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing
valve ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
for cold water connection only.
Electrical connection
Connect the appliance to an
alternating current only, ranging from
220 V to 240 V and 50 Hz or 60 Hz
via a correctly installed socket with
protective earth conductor. See
rating plate for required fusing
9*
.
The socket must be near
the appliance and freely accessible
following installation.
If the plug is not freely accessible, an
allpole disconnector with a contact
opening of at least 3 mm must be
fitted on the installation side
to satisfy the relevant safety
instructions.
The connection may be modified by
technicians only.
A power cord extension may be
purchased from customer service
only.
Use only a residual current operated
circuit-breaker which features
the symbol
‚
. Only this extension
guarantees compliance with
the currently valid regulations.
The appliance features a water
damage protection system. Please
note the system will not function
unless
the power supply
is connected.