15
Bosch Security Systems 12/14 BLCC610U
Solution 6000 User Guide
The keypad will display the current user name.
User Name Ur1
User 1 Name
Press
OK to SAVE
3. Use the [
] and [
] keys to scroll the cursor left
and right across the user name text. Use the [
] and
[
] keys to scroll through the different characters
available. To clear all text from the cursor position,
press the [OFF] key.
4. When the user name is complete, press [OK] to save
and exit, or press [MENU] to exit without saving.
Access > User Properties >
Area Assignment
MENU 1-4-1
This menu allows the master user to program which areas
(1 to 8) a user can access. Each user can be assigned to
one or multiple areas. The master user is restricted and can
only assign another user to any one or multiple areas that
the master user has been assigned to. At factory default,
each user is assigned to operate Area 1.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [1] + [4] + [1].
A list of users will display on the keypad.
2. To assign areas to a user, use the [
] and [
] keys to
select the user that you want to program, then press
[OK] to select. Alternatively, you can enter the user
number you want to program, then press [OK].
The keypad will display which areas the user has
been assigned to.
Security System
Area 2 Name
Area 3 name
Press
OK ON OFF MENU
3. Use the [
] and [
] keys to select the area that
you want to assign to the user. Press the [ON] key
to assign the user to the area (√ will display) or
press the [OFF] key to disable the user from the
corresponding area (√ will no longer display).
4. Repeat Step 3 until you have assigned the user to all
areas that are required.
5. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Access > User Properties >
User Options
MENU 1-4-2
This menu allows the master user to set or change various
options for other users on the system. You should discuss
these options with your installer before making changes.
Follow the procedure below to configure the required
options.
1. Enter your Master PIN + [MENU].
2. Enter [1] + [4] + [2] + [OK].
The keypad will display the list of current options.
Options with a preceeding tick mark are selected.
Master User
Reserved
Arm Only
Press
OK ON OFF MENU
3. Use the [
] and [
] keys
to highlight the feature that
you want to program, then use the [ON] and [OFF]
keys to turn on and off the features as required.
4. When all user options are programmed, press [OK] to
save and exit, or press [MENU] to exit without saving
.
TimeZones
Timezones can be used to restrict users from operating
doors or from controlling the alarm system outside given
times of the day, days of the week or during holidays.
A master code holder is able to change the timezone
parameters so they can control the access times for a given
user. If a resticted user tries to operate the system outside
their assigned timezone then access will be denied.
See MENU 7-5-0 for more information on timezone
programming.
Access > User Properties >
TimeZone Access
MENU 1-4-4
This menu is used to assign a user to a timezone. Timezones
can be used to restrict a users access to be within specific
times of the day and or days of the week. Each User can
only be assigned to one timezone. Setting this option to
timezone 1 will give the user 24 hour access to the system.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [1] + [4] + [4] and select the user
from the list then press [OK].
Ur1 John Smith
Ur2 Debbie Smith
Ur3 User 3 Name
Press
OK or MENU
2. Using the numeric keys, enter the timezone.
Valid entries are 1 – 16 or 0 to disable.
TimeZone Access Ur1
01 - 24 Hour TimeZone
Press
0-9 OK to SAVE
3. Press [OK] to save and exit or press [MENU] to exit
without saving.