Solution 144
Security System
Quick Start Guide
EN
Security Systems
Страница 1: ...Solution 144 Security System Quick Start Guide EN Security Systems ...
Страница 2: ...e The grant of a Telepermit for a device in no way indicates Telecom acceptance of responsibility for the correct operation of that device under all operating conditions This equipment shall not be used in any manner that could constitute a nuisance to other Telecom customers Immediately disconnect this equipment should it become physically damaged and arrange for its disposal or repair The transm...
Страница 3: ...s 14 Board Connectors 14 ABOUT THE KEYPAD 15 Status Icons LED s 16 Keypad Tones 16 Keypad Readers Setup 17 DIP Switch Address Select 17 Rotary Switch Address Select 17 DTMF Control Functions 18 Programming Overview 18 Entering Programming Mode 18 Exiting Programming Mode 18 Navigating The Menu 18 Command Menu 19 Programming Option Bit Menus 19 Alpha Text 19 Telephone Numbers 19 List Options 19 Clo...
Страница 4: ...rt Expansion Module Supervision DTMF Tone Decoder Built In Remote Arming Fingetprint Reader Options Overview Zones The Solution 144 control panel provides up to 144 separate zones of protection Zone programming determines the panel s response to open short and tamper conditions on the zone loop Areas The control panel supports up to 8 separate areas You can assign all zones to a single area or you...
Страница 5: ...et to suit the installation Before installing the bracket fit the tamper lead to the switch and then insert it into the bracket Once the enclosure has been mounted to the wall insert the tamper bracket into the rectangular hole in the top flange of the enclosure and then slide the base of the bracket toward the top until the tamper switch locates in the rear of the enclosure Depress the tamper a f...
Страница 6: ...ll modules only 4 clips are required 1 in each corner Both enclosures are supplied with tamper switches tamper leads tamper brackets and a quantity of mounting clips and screws If required additional mounting clips and screws may be purchased in bags of 50 clips 10 packs x 5pcs P N MW890 i Note The supplied mounting clips are designed to use the 3mm machine screws supplied with the enclosure The u...
Страница 7: ...sure Details The following examples show the MW710 Large enclosure configured using 6 small modules and 1 large module CABLE ENTRY REAR MODULE SPACE 1 MODULE SPACE 3 MODULE SPACE 2 MODULE SPACE 5 MODULE SPACE 4 MODULE SPACE 7 MODULE SPACE 6 CABLE ENTRY REAR CABLE ENTRY REAR When installing small modules you should fit 4 mounting clips as shown When installing large modules you should fit 5 mounting ...
Страница 8: ...rmer depending on the model and country of sale When connecting using the AC adapter feed the cable in to the enclosure and terminate the wires on the removable terminal block supplied before connection it to the PCB If using a 3 wire adaptor then the earth wire should also be terminated onto the terminal block Always check the orientation of the terminal block with the PCB markings before connect...
Страница 9: ...y Open Alarm Contacts When using Normally Open Alarm Contacts you must select Inverted Seal for each zone in MENU 3 1 8 A shorted loop is a tamper condition for all EOL zone configurations 2 ZONE 2 N O N O ZONE 1 ZN 1 GND ZN 2 Figure 13 N O No EOL Zone ZONE 2 ZONE 1 N O N O ALARM ALARM ZN 1 GND ZN 2 Figure 14 N O Single EOL Zone 6K8 EOL 3K3 EOL N O N O ALARM ALARM ZN 1 GND ZN 2 ZONE 9 ZONE 1 Figur...
Страница 10: ... shielded cable can be used successfully in many situations however for the highest reliability and performance in areas prone to frequent electrical storms or high levels of electrical interference shielded twisted pair cable should be used LAN and LAN should not be used to power detectors or other external devices These devices should be powered from the 12V terminals on the panel or via an exte...
Страница 11: ... is installed do NOT connect the EARTH wire from any 3 wire plug pack to any modules EARTH input terminal If a separate communications earth is NOT being used then you should connect the earth wire from the 3 wire plug pack to the panels earth terminal as shown in Figure 19 When using shielded cable the shield of each length of cable should only be connected to a protective earth at one end Do no ...
Страница 12: ...Keyswitch Input Zone Input Terminals Telephone Line Connection Terminals Telephone Line Connection Socket RJ12 6P4C Panel Cabinet Tamper Circuit Connection Terminals Battery Charging Globe Voice Module Connection Socket Optional 4 Pin Socket to LAN For Service Keypad Default and Direct Connect Switch 10 Pin Serial Connection Socket For Direct Link Flash Programming etc Relay COM Terminal Programmi...
Страница 13: ...be Light 12V DC 7 2AH Sealed Lead Acid Battery Accessories e g PIR Detectors Siren Tamper Switch Connect To Cabinet Tamper To Zone Terminals NC COM RJ12 6P4C RJ12 6P4C Phone Lead Connect To Telephone Line Mode 3 Smoke Detector RF Receiver Connect To Accessory Power GND 12V RF DATA Earth Connection Spade For Surge Protection Panasonic LC P127R2P or Equivalent Ouput 5 Relay Output 24V D C 2Amp Relay...
Страница 14: ... Zone 3 and 11 sensor loop input 29 GND Common for Zone 3 and 4 sensor loop 30 ZN 4 Zone 4 and 12 sensor loop input 31 ZN 5 Zone 5 and 13 sensor loop input 32 GND Common for Zone 5 and 6 sensor loop 33 ZN 6 Zone 6 and 14 sensor loop input 34 ZN 7 Zone 7 and 15 sensor loop input Nº Name Description 35 GND Common for Zone 7 and 8 sensor loop 36 ZN 8 Zone 8 and 16 sensor loop input 37 38 IN IN These ...
Страница 15: ...lows you to save any changes and exit the command The MAIL key allows you to read stored mail This key can also be used to initiate a dialler test when you press and hold for two seconds The key allows you to move the cursor left when programming text or telephone numbers The key allows you to move the cursor right when programming text or telephone numbers The key allows you to navigate through m...
Страница 16: ...ngs Keypad Tones All keypads emit several distinct tones and display text to alert you to system events The volume of the keypad tones can be adjusted in MENU 6 1 0 Type Meaning Fire Alarm Tone When a fire zone sounds an alarm the keypad will sound 3 seconds on and 2 seconds off repeat Burglary Alarm Tone When a burglary zone activates while your system is turned on your keypad emits a continuous ...
Страница 17: ...actorysettoaddress 1 OFF OFF OFF OFF DIP Switch Address Select 4 Figure 23 Keypad DIP Switch Address Settings DIP Switch Address Settings Keypad Reader No S1 S2 S3 S4 1 Off Off Off Off 2 On Off Off Off 3 Off On Off Off 4 On On Off Off 5 Off Off On Off 6 On Off On Off 7 Off On On Off 8 On On On Off 9 Off Off Off On 10 On Off Off On 11 Off On Off On 12 On On Off On 13 Off Off On On 14 On Off On On 1...
Страница 18: ...o 2 High Low End Session High Medium Low Table 11 DTMF Remote Control Functions DTMF EXAMPLES Each example below shows the log on step for clarity In practise is only necessary to log on once per DTMF control session To turn Area 1 ON enter the following 2 5 8 0 Log ON 1 1 1 Arm Area 1 To turn Output 10 ON enter the following 2 5 8 0 Log ON 2 1 0 1 Turn Output 10 ON To turn Output 12 OFF enter the...
Страница 19: ...through the available characters assigned to the key The text key layout is the same as most phones Refer to the table below for detailed character information Key Characters Assigned To Each Numeric Key 1 1 2 A B C a b c 2 3 D E F d e f 3 4 G H I g h i 4 5 J K L j k l 5 6 M N O m n o 6 7 P Q R S p q r s 7 8 T U V t u v 8 9 W X Y Z w x y z 9 0 SPACE 0 Scroll Up through entire character list Scroll...
Страница 20: ...U 5 1 2 8 Press and hold down MENU to exit Service Mode Service mode when activated disables dialler reporting prevents all alarms and prevents all users from arming the system To Turn Service Mode ON 1 Enter programming mode 1 2 3 4 MENU 2 Turn service mode on MENU 7 0 8 3 Follow display prompts 4 Hold down MENU to exit i Note Keypads will display the word Service when service mode is active To T...
Страница 21: ... seconds to initiate the programming session See Figure 20 for the default switch location It is also possible to initiate the programming session via MENU 5 0 5 Start Direct Link Zone Array The feature allows you to view the condition of all zones on the panel in banks of 16 zones at a time From the installer programing mode press MENU 3 0 1 to access the zone array Use the and arrow keys to scro...
Страница 22: ...yproductsoutlet Your base station will need to create a specific reporting template for this and other new model Solution panels Point ID Table Module Description Ur999 Installer Ur998 Remote User Ur997 TimeZone Ur996 Guard Tour Ur001 995 Users Ur000 Quick Arm Zn001 200 Zones General Zn201 264 Doors 1 64 or Zones 201 264 Zn301 428 User Keyfob 1 128 Zn429 556 User Keyfob 129 256 Zn701 708 Door Cont...
Страница 23: ...ew PIN MI 7 1 0 Set Date And Time 2 1 Area Properties UMI 3 0 5 Smoke Sensor Reset 1 2 Token MI 2 1 0 Area Name UMI 3 9 0 Walk Test All Zones MI 1 2 0 Add Token I 2 1 1 General Options MI 4 9 0 External Siren Test MI 1 2 1 Delete Token I 2 1 2 Input Options MI 4 9 1 Internal Siren Test MI 1 2 2 Token Status I 2 1 3 Output Options MI 4 9 2 Strobe Test MI 1 2 3 Edit Token I 2 1 4 Reporting Options U...
Страница 24: ... I 3 1 7 Report Options 4 2 Door Properties I 3 1 8 Zone Options MI 4 2 0 Door Name 5 2 Properties I 4 2 2 Unlock TimeZone I 5 2 0 Call Attempt Count 3 3 RF Zone I 4 2 3 Door Options I 5 2 1 Dialler Options I 3 3 0 Add RF Device I 5 2 2 Phone Line Options I 3 3 1 Delete RF Device 4 9 Output Testing I 5 2 3 Country I 3 3 2 Test RF Device MI 4 9 0 External Siren Test I 5 2 7 Set SMS Password MI 4 9 ...
Страница 25: ... 5 IPRS Address I 6 1 8 Lockout Time I 7 3 0 AC Options I 5 7 6 IPRS Port I 7 3 1 Battery Options 6 2 RF Devices I 7 3 2 Fuse Options 5 9 Comms Test I 6 2 0 Receiver Options UMI 5 9 0 Send Test Report I 6 2 1 Supervision Time 7 4 Siren I 5 9 1 Test Report Time I 6 2 2 RF Device Options I 7 4 0 Tone I 5 9 2 Test Report Period I 6 2 3 Add RF Keypad I 7 4 1 Speed I 5 9 3 Test Report Options I 6 2 4 D...
Страница 26: ...Can Bypass Y Y Auto Bypass Y Y Always Report Op Cl Y Y TimeZone 01 01 Door Assignment Table 18 User Default Programming Options Access RF Keyfob Add Keyfob MENU 1 3 0 Delete Keyfob MENU 1 3 1 Test Keyfob MENU 1 3 2 Access User Properties User Name MENU 1 4 0 U s e r 1 N a m e Use the and keys to scroll cursor left and right Use the 0 9 keys or the and keys to scroll characters then press OK to sav...
Страница 27: ...each user Press 1 16 then press ON or OFF to toggle door on off then press OK to save Access User Properties User Expire Date MENU 1 4 6 Access Global Properties PIN Length MENU 1 5 0 System Wide Parameter 0 4 00 Variable 03 3 Digits 06 6 Digits 01 1 Digit 04 4 Digits 07 7 Digits 02 2 Digits 05 5 Digits 08 8 Digits Enter 00 08 OK to program the PIN length Access Global Properties PIN Retry Count M...
Страница 28: ...rt Off N Use the and keys to scroll the list of options Select the option required then press ON or OFF to enable or disable A will display to indicate option set Press OK to save when finished Areas Properties Input Options MENU 2 1 2 1 Non Sequential Y 2 Pulse Count H Over Y 3 Senior Watch N 4 Reset Smoke On Arming Y 5 Reserved N 6 Reserved N 7 Reserved N 8 Reserved N Use the and keys to scroll ...
Страница 29: ... 04 TimeZone 4 Name 12 TimeZone 12 Name 05 TimeZone 5 Name 13 TimeZone 13 Name 06 TimeZone 6 Name 14 TimeZone 14 Name 07 TimeZone 7 Name 15 TimeZone 15 Name 08 TimeZone 8 Name 16 TimeZone 16 Name Enter 0 16 OK to assign the area to a TimeZone Can only be assigned to one TimeZone 0 Disabled To set the start stop and days of the week that the area will automatically arm refer to TimeZone menu s Area...
Страница 30: ... Use the and keys to scroll the list of options Select the option required then press ON or OFF to enable or disable A will display to indicate option set Press OK to save when finished Input Programming Inputs Commands Zone Status MENU 3 0 0 Zone Array MENU 3 0 1 Bypass Zones MENU 3 0 2 Set Chime Zones MENU 3 0 3 Set Part 2 Zones MENU 3 0 4 Smoke Sensor Reset MENU 3 0 5 Inputs Zone Properties Zon...
Страница 31: ...can be assigned to each zone Use the and keys to highlightdoor name then press OK to save Inputs Zone Properties Report Route MENU 3 1 6 00 Log Events Only 0 1 01 Dest 1 Log 02 Dest 2 Log 03 Dest 1 2 Log 04 Dest 2 If 1 Fails Use and keys or enter 0 4 OK to set the destination zone reports are sent to Zone Assignments Zone Assignment Table Module Number Address Setting Zone Numbers Single EOL Zone ...
Страница 32: ... 5 Handover 3 Instant 0 Not Used Area Assignment 1 1 1 1 1 1 Pulse Count 0 0 0 0 0 0 Pulse Count Time 120 120 120 120 120 120 Door Assignment 0 0 0 0 0 0 Report Route 2 2 2 2 2 2 Reporting Options Lockout Dialler Y Y Y Y Y Y Report Alarm Y Y Y Y Y Y Report Troubles Y Y Y Y Y Y Report Bypass Y Y Y Y Y Y Report Restores Y Y Y Y Y Y Delay Reporting N N N N N N Zone Options Lockout Siren Y Y Y Y Y Y S...
Страница 33: ...Open Close Y 6 Alarm On Tamper N 7 Reserved N 8 Reserved N System Wide Parameter Use the and keys to scroll the list of options Select the option required then press ON or OFF to enable or disable A will display to indicate option set Press OK to save when finished Inputs PGM Input Keyswitch Options MENU 3 5 0 0 0 00 Disabled 03 Simple RF On Off 01 Latching On Off 04 Bosch Serial Rcvr 02 Pulse On ...
Страница 34: ... Parameter N Of Hours 000 008 000 000 000 000 N Of Minutes 005 000 000 005 000 000 N Of Seconds 000 000 010 000 002 000 N Of 1 10 Seconds 000 000 000 000 000 000 Output Options Off On Low Battery Y Y N Y N N Guest Control N N N N N N Reserved N N N N N N Monitor Overload Y Y Y Y N N Monitor Device Fail Y Y N Y N N Alarm On Device Fail N N N N N N Block If All On N N N N N N Show Status On Keypad N...
Страница 35: ... CLI Trigger CLI 11 Dialler Disabled P 37 Internal Audible A 72 GSM Signal Lost P 12 Output Device Missing P 38 Any Zone Alarm A 73 GPRS Failure P 13 Output Trouble Op 39 Fire Alarm A 74 Ethernet Fail P 14 Panel On Line P 40 Burglary Alarm A 75 Macro Ma 15 Incoming Call P 41 Silent Alarm A 16 System Trouble P 42 Duress Alarm A 17 Box Tamper Zn 43 Keypad Medical A 18 Zone Trouble Zn 44 Keypad Fire ...
Страница 36: ...eypad or Access Group Number etc you want the output to follow then press OK Outputs Properties Output Polarity MENU 4 1 3 0 0 00 Open To Low 08 Low To Open Pre 01 Open To Low Pre 09 Low Latching Open 02 Open Latching Low 10 Low Pulsing Open 03 Open Pulsing Low 11 Low 1 Shot Open 04 Open 1 Shot Low 12 1 Shot Open Retrigger 05 1 Shot Low Retrigger 13 1 Shot Open Reset 06 1 Shot Low Reset 14 Speaker...
Страница 37: ...imeZone 9 Name 02 TimeZone 2 Name 10 TimeZone 10 Name 03 TimeZone 3 Name 11 TimeZone 11 Name 04 TimeZone 4 Name 12 TimeZone 12 Name 05 TimeZone 5 Name 13 TimeZone 13 Name 06 TimeZone 6 Name 14 TimeZone 14 Name 07 TimeZone 7 Name 15 TimeZone 15 Name 08 TimeZone 8 Name 16 TimeZone 16 Name A single TimeZone can be assigned to each door Use the and keys to highlight door name then press OK to select E...
Страница 38: ...elephone digits Use and to toggle special characters and Pause Comms Telephone Numbers Destination 1 MENU 5 1 1 Phone 1 1 Digits 32 Phone 2 1 Digits 32 Phone 3 1 Digits 32 Phone 4 1 Digits 32 Phone 5 1 Digits 32 Use and keys to scroll cursor Enter 0 9 for telephone digits Use and to toggle special characters and Pause Comms Telephone Numbers Destination 2 MENU 5 1 2 Phone 1 1 Digits 32 Phone 2 1 D...
Страница 39: ...ve when finished Comms Properties Country MENU 5 2 3 System Wide Parameter 0 1 Ln1 AUSTRALIA Ln9 CZECH REPUBLIC Ln2 NEW ZEALAND Ln10 POLAND Ln3 ITALY Ln11 TURKEY Ln4 GREECE Ln12 CHINA Ln5 CYPRUS Ln13 HONG KONG Ln6 SPAIN Ln14 MALAYSIA Ln7 PORTUGAL Ln15 BRAZIL Ln8 HUNGARY Use and keys or enter 0 15 OK to set which country the panel is being used in Only 1 option can be programmed Comms Properties Se...
Страница 40: ... Note Up to 3 Phone numbers can be entered for CLI Call Line Identification for remote access detection YoumustenterSTDcodeplusthecompetenumber for this option to work Press OK after each telephone number is entered to save and move to the next number Comms Remote Access User RAS PIN MENU 5 3 8 0 0 0 0 0 0 0 0 Use keys 0 9 to program User RAS Security PIN OK to save Comms Reporting TX Format Dest ...
Страница 41: ...MENU 5 5 0 Factory Set Comms MyAlarm IP Port MENU 5 5 1 Factory Set Comms MyAlarm MyAlarm Options MENU 5 5 2 1 Reserved N 2 Reserved N 3 Reserved N 4 Reserved N 5 Reserved N 6 Reserved N 7 Reserved N 8 Reserved N Use the and keys to scroll the list of options Select the option required then press ON or OFF to enable or disable A will display to indicate option set Press OK to save when finished i ...
Страница 42: ...stination 2 Comms IP Reporting ACK Wait Time MENU 5 6 3 0 1 0 Seconds Enter 0 255 OK to program the acknowledge wait time in seconds for both Destination 1 and or Destination 2 Comms IP Reporting IP Format MENU 5 6 4 00 Conettix 0 1 01 Conettix NNC Anti Replay 02 CSV IP ALARM 03 Suretek TBA 04 Permacom TBA 05 Direct Wireless TBA 06 MyAlarm CID TBA Enter 0 5 OK to program the IP format for both Des...
Страница 43: ...dress then press OK to save when finished Comms IP Remote Access IP Port MENU 5 7 1 Installer 0 7 7 0 1 User 0 7 7 0 1 Enter IP Port must be 5 digits within the range 0 to 65535 Use and keys to scroll cursor Press OK to save Comms IP Remote Access IP RAS Options MENU 5 7 2 1 IP RAS Allowed Y 2 IP RAS Only If Disarmed N 3 Report IP Session Y 4 Report IP Lockout Y 5 UDP Installer RAS Y 6 UDP User RA...
Страница 44: ...e digits to dial and press OK The system will call the number entered This function will stop after 30 seconds or by pressing OK Enter 0 9 for telephone digits Use and to toggle special Characters and Pause Device Programming Devices Commands Device Status MENU 6 0 0 LAN Secure MENU 6 0 1 LAN Scan MENU 6 0 2 LAN Watch MENU 6 0 3 Keypad Volume MENU 6 0 7 Keypad Contrast MENU 6 0 8 Keypad Backlight ...
Страница 45: ...eserved N Use the and keys to scroll the list of options Select the option required then press ON or OFF to enable or disable A will display to indicate option set Press OK to save when finished Devices Keypads Readers Door Assignment MENU 6 1 7 0 0 00 No Door Assignment 01 Door 1 Name 09 Door 9 Name 02 Door 2 Name 10 Door 10 Name 03 Door 3 Name 11 Door 11 Name 04 Door 4 Name 12 Door 12 Name 05 Do...
Страница 46: ...Flow Control MENU 6 3 2 00 No Handshaking 0 0 01 Hardware 02 Xon Xoff Use and keys or enter 0 2 to program the serial device flow control then press OK to save Devices GSM GPRS Module GSM GPRS Status MENU 6 5 0 This command interrogates the GSM module and displays infomration about the radio and the SIM installed The first line is a heading which indicates the GSM module type that is installed Typ...
Страница 47: ...lephone numbers can be entered for Table 1 Press OK after each telephone number is entered to save and move to the next telephone number Devices GSM GPRS Module CLI Trigger Table 2 MENU 6 5 5 1 Phone 1 1 Digits 16 Phone 2 1 Digits 16 Phone 3 1 Digits 16 Phone 4 1 Digits 16 Phone 5 1 Digits 16 Phone 6 1 Digits 16 Phone 7 1 Digits 16 Phone 8 1 Digits 16 Phone 9 1 Digits 16 Phone 10 1 Digits 16 Use a...
Страница 48: ... 0 0 0 0 0 0 0 0 0 0 0 0 This can be found by running IPCONFIG on a PC connected to the clients network Typical Subnet mask is 255 255 255 0 Devices Ethernet Module Default Gateway MENU 6 6 2 0 0 0 0 0 0 0 0 0 0 0 0 This gateway IP address can be found by running IPCONFIG on a PC connected to the clients network Devices Ethernet Module Module MAC Address MENU 6 6 3 0 0 0 0 0 0 0 0 0 0 0 0 This is ...
Страница 49: ... scroll cursor left and right and use and to toggle options System Clock Locale MENU 7 1 3 System Wide Parameter 0 0 00 Disabled 01 SYDNEY 04 ADELAIDE 02 MELBOURNE 05 PERTH 03 BRISBANE 06 HOBART MENU 7 1 3 programs the locale in Australia Use and keys or enter 0 to 15 OK to program System Power AC Options MENU 7 3 0 1 Display AC Fail Y 2 Report AC Fail Y 3 Sync Clock To AC Y 4 Random AC Report 2hr...
Страница 50: ...nter the disarm time in the start time field of the same timezone period For example if you want the system to disarm at 7 30am you would program 07 30 00 in the stop field See the full installation manual for more details System Power Fuse Options MENU 7 3 2 1 Display COMM O Load Y 2 Report COMM O Load Y 3 Display 12v O Load Y 4 Report 12v O Load Y 5 Display LAN O Load Y 6 Report LAN O Load Y 7 R...
Страница 51: ...AN Fail Y 3 Alarm On LAN Fail N 4 Cannot Change Own PIN N 5 Reserved N 6 Monitor Default PINs Y 7 PIN Always Required N 8 Display Menu Numbers Y System Wide Parameter Use the and keys to scroll the list of options Select the option required then press ON or OFF to enable or disable A will display to indicate option set Press OK to save when finished System System Options Area Options MENU 7 7 1 1 ...
Страница 52: ...on System System Testing Walk Test All Zones MENU 7 9 0 Battery Test MENU 7 9 1 Testing The System You will need to be in programming mode before accessing the test functions listed below Walk Test Use the walk test command MENU 3 9 0 to test and verify that all zones work correctly External Audible Test Use MENU 4 9 0 to test and verify that all horn speakers operate This test will sound the horn...
Страница 53: ...53 Bosch Security Systems 10 12 BLCC600R Solution 144 Quick Start Guide ...
Страница 54: ...Quick Start Guide Installation Details CUSTOMER NAME PHONE INSTALLED BY DATE ACCOUNT N PANEL LOCATION PANEL PHONE N CLI ENABLED N WIRED ZONES N OF USERS N RF ZONES N OF AREAS WARRANTY EXPIRES COMMON AREA USED USER TRAINING COMPLETED BY PERSON TRAINED NOTES ...
Страница 55: ...provided Relative Humidity 5 to 85 non condensing Compatible Keypads CP700B Graphic Keypad White CP701B Graphic Keypad Prox White CP710B Graphic Keypad Black CP711B Graphic Keypad Prox Black Compatible Accessories CM704B 8 16 Zone Expander CM710B 4 Way Relay Output Module CM720B 1 Amp LAN Power Supply CM195B Multi RF Receiver Interface CP150B External Vandal Resistant Keypad CP151B Slim Style Vand...
Страница 56: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2128 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2012 Bosch Security Systems BLCC600R Issue FTR1 1 ...