18 Installation
RVON+
Jumpers and Configuration
J1 Configuration File Save Location
The RVON+ has only one jumper that can be configured. The J1 jumper controls where the RVON+ configuration file is
stored; either on the master controller card or on the RVON+ card. In both AZedit and IPedit, this option is seen as a status
only (grayed out) check box.
IMPORTANT
:
You must remove the card from the frame in order to make changes to the jumper setting.
If the J1 pins are shorted, the RVON+ card uses the configuration stored in its local Flash EPROM.
If the J1 pins are clear, the RVON+ card uses the configuration received from the MCII-e.
NOTE:
Jumper J5 has no functionality. Cards ship from the factory with a jumper installed on J5. If a jumper is needed
for J1, then the J5 jumper can be used. Once the J1 jumper isn’t needed, the jumper can be stored at J5.
FIGURE 6.
J1 Jumper