9.2.6
DS7400XiV4-EXP
–
Phone Number Fields Also Apply to IP Addresses: The phone number fields in
Phone
Control
and
Partitions > Account Code
also support IP addresses if you are
communicating over an Ethernet network.
–
Resetting the Control Panel from RPS Clears Date and Time Settings:
If you click the
Reset Panel checkbox on the End Session dialog, RPS clears the control panel's date and
time settings. You cannot retrieve current history events if these settings are cleared. You
must retrieve all of the control panel's history log entries.
–
If you cannot connect to a DS7400XiV4-EXP using a Hayes 2400 Modem, use the
following initialization (init) string:
AT&C1&D2X0&Q0S9=1S7=255S10=254.