Loss of UL/CSA conformity due to modifications at the device.
UL and CSA marking applies only to the device upon delivery. After
modifying the device, verify the UL and the CSA conformity.
9 Interfaces
1
2
3
4 5 6
7 8
Fig. 9-1: Interfaces of the built-in devices (for names, refer to the following table)
1
2
3
4 5 6
7
Fig. 9-2: Interfaces of the housing devices (for names, refer to the following table)
9.1 Overview
Name at the
housing
Connection type
Connector type, inte-
grated
Mating connector or ca-
ble (from outside)
①
XD1
24 V DC voltage supply
3-pin, MC1,5/3- G-3,5
THT
3-pin, FK-MCP 1,5/3-
ST-3,5
②
XF20
Gigabit Ethernet interface
RJ45 socket
RJ45 plug
③
XF21
Gigabit Ethernet interface
RJ45 socket
RJ45 plug
④
XBAT
Battery connection
Molex Micro-Fit 3 mm Molex 43645-0200
(or compatible)
⑤
XG10
CFAST slot
CFAST socket
CFAST card
Bosch Rexroth AG
Interfaces
VEP 15.6 Multi Touch, VEP 21.6 Multi
Touch
16/53
DOK-SUPPL*-VEPXX.6MTHU-IT02-EN-P
Содержание Rexroth VEP 15.6 Multi Touch
Страница 6: ...Bosch Rexroth AG VEP 15 6 Multi Touch VEP 21 6 Multi Touch IV DOK SUPPL VEPXX 6MTHU IT02 EN P ...
Страница 57: ...VEP 15 6 Multi Touch VEP 21 6 Multi Touch Bosch Rexroth AG DOK SUPPL VEPXX 6MTHU IT02 EN P 51 53 ...
Страница 58: ...Bosch Rexroth AG VEP 15 6 Multi Touch VEP 21 6 Multi Touch 52 53 DOK SUPPL VEPXX 6MTHU IT02 EN P ...
Страница 59: ...Notes VEP 15 6 Multi Touch VEP 21 6 Multi Touch Bosch Rexroth AG ...