Safety instructions
Please observe the safety-relevant information and risk specifications in the
•
operating instructions of the manufacturer of the connected hydraulic system
before commissioning the control with a hydraulic system.
Please observe the general installation and safety instructions when working on
•
electric systems.
The information given in the product documentation with regard to the use of
•
the supplied components are only application samples and recommendations.
The machine manufacturer and system installer must check the suitability of
the supplied components and the information given in this documentation with
regard to their use self-dependently for his individual application and adjust it to
the safety instructions and standards valid for his application, and carry out the
required measures, changes and amendments.
Technical data as well as connection and installation conditions are available in
•
the product documentation and must be imperatively observed.
Personal protection is to be ensured by monitoring or measures which are
•
superior to the system. The SYHNC100-SEK..3x itself is no safety-relevant
component.
You must generally not modify or retrofit the product.
•
Product- and technology-related safety instructions
2.6
Dangerous motions
•
It is not allowed for persons to stay within the range of motion of machines
and machine parts. The following are examples of possible measures against
unintended access of persons:
Protective fences
–
Protective grids
–
Protective covers
–
Light barrier
–
If persons must access the danger zone during active control, monitoring
•
or measures must be provided for personal safety which are superior to the
system. These measures must be provided according to the specific data
of the system and on the basis of the risk and failure analysis of the system
manufacturer/user. In this connection, the safety requirements applied for the
system must be taken into account.
The SYHNC100-SEK...3X itself does not include any safety functions for
•
personal safety and is no safety-relevant component. The SYHNC100-SEK...3X
is solely used for closed-loop speed control, closed-loop torque control as well
as open-loop torque control of secondary controlled axes.
In case of failures impairing the safety and modifications to the operating
•
behavior, shut down the SYHNC100-SEK...3X immediately and report the
failures to the responsible personnel.
High electrical voltage as a result of incorrect connection!
•
Danger of life, risk of injuries caused by electric shock!
Only use power packs with protective extra-low voltage (PELV) and/or if they
–
are safely separated from the mains circuits. For further information please
see IEC 60204-1.
All connections and clamps with voltages between 0 and 50 Volt may only be
–
connected with devices, electric components and lines with a protective extra-
low voltage (PELV).
Only connect voltages and electric circuits provided with a safe isolation from
–
dangerous voltages. Safe electrical isolation can be achieved for example
with isolating transformers, safe optocouplers or mains-free battery operation.