RE 30011-B, Edition 10.2021, Bosch Rexroth AG
Demounting and replacement |
Pressure and flow control system SYDFE1 series 2X, 3X
77/96
12 Demounting and
replacement
12.1 REQUIRED TOOLS
The product can be demounted using standard tools. No special tools are
necessary.
12.2 PREPARING DEMOUNTING
1.
Decommission the entire system as described in the general instructions for
the machine or system.
2.
Depressurize the hydraulic system according to the instructions of the machine
or system manufacturer.
12.3 DEMOUNTING
Proceed as follows to demount the SYDFE1 control system:
1.
Make sure that the hydraulic system is depressurized.
2.
Check that the SYDFE1 control system has cooled down sufficiently so that it
can be demounted without any risks.
NOTICE
! Spilled or discharged hydraulic fluid!
Environmental damage and contamination of the groundwater!
▶ When filling in and changing the hydraulic fluid, always place a catch pan under
the SYDFE1 control system.
▶ Observe the information in the safety data sheet for the hydraulic fluid and the
instructions provided by the system manufacturer.
1.
Loosen the lines and collect the escaping hydraulic fluid in the collector
provided for this purpose.
2.
Demount the SYDFE1 control system. Use suitable lifting gear for this.
3.
Drain the SYDFE1 control system completely.
4.
Plug all openings.
12.4 PREPARING THE COMPONENTS FOR STORAGE OR
FURTHER USE
▶ Proceed as described in chapter 6.2 “Storing the SYDFE1 control system” on
page 41.