R911336855-04_BAL_DOC
January 18, 2016
Page 4 of 7
9
Interfaces
The connector blocks on the circuit board at
the rear side plugs into the system backplane of
the system housing. More information is avail-
able in the NYCe 4000 Hardware System
Manual.
10 Installation and Removal
______________________________________
Damage to components
may occur if power is applied during instal-
lation or removal.
Make sure power supplies are switched
off before installation or removal of the
system housing.
Do not apply power until the drive mod-
ule is installed.
______________________________________
______________________________________
Damage to components
may occur if drive power voltage is too high.
Make sure that the DP drive voltage is
changed (lowered) before you install the
NY4125 drive module in a drive slot
previously configured for an NY4120 or
NY4140 drive module.
______________________________________
______________________________________
Damage to components
may occur due to electrostatic discharges.
Comply with all ESD protective
measures while working with modules
and components. Avoid electrostatic dis-
charges.
______________________________________
______________________________________
Damage to components
may occur if installed in the wrong system
housing.
Make sure this drive module is only
installed in the NYS04.1-ST-03-4125-
NY4063 system housing.
Make sure this drive module is only in-
stalled in drive slot 0, marked “NY4125”.
______________________________________
Power supplies must be switched on/off
with the disconnecting device installed in the
cabinet.
The drive module may only be used as
build-in equipment, which means that the end-
user must provide a suitable fire and electrical
safe enclosure.
The drive module may only be used in
combination with external approved power
supplies. The supply voltages 24V System,
24V Dig, and 24V Fdig for the system must be
separated at least by reinforced insulation from
all hazardous voltages according to the stand-
ard UL61010-1 third edition.
10.1
Mechanical Dimensions
The dimensions of the drive module are the
following:
You can see the dimensions of the drive mod-
ule in the following views.
10.2
Installation of the Drive Module
The drive module is intended for installation in
the
NY4063
system
housing
with
a
Bosch Rexroth backplane. The drive module is
always installed in the slot marked with the
text ‘NY4125’.
Position the drive module in the front slot
guides and gently slide the module into the
slot. Align the connectors of the module with
the connectors on the system backplane. Then
push the module into the connector. Do
not
use
excessive force to prevent damage to the con-
nector pins.
In Betrieb
Lagerung und
Transport
Max. Um-
gebungs-
temperatur
+5 ... +55 °C
-25 °C bis +70 °C
Relative
Feuchte
RH-2; 5 % bis 95 % nach
DIN EN 61131-2, Betau-
ung nicht zulässig.
RH-2; 5 % bis 95 %
nach DIN EN 61131-2,
Betauung nicht zulässig.
Luftdruck
Bis 2700 m über NN nach
DIN 60204
Bis 3000 m über NN
nach DIN 60204
Mechani-
sche Fes-
tigkeit
Max. Vibration:
Frequenzbereich:
10...150 Hz
Auslenkung: 0,075 mm
bei 10...57 Hz
Beschleunigung: 1 g
bei 57...150 Hz
Nach EN 60068-2-6
Max. Schock: 15 g nach
EN 60 068-2-27, keine
Störung der Funktion
Typecode
Width
Height
Depth
NYM04.1-5PW-NNNN-NY4125
21.7
mm
128.4
mm
148.5
mm