background image

 

R911336855-04_BAL_DOC 

January 18, 2016 

Page 4 of 7 

Interfaces 

The  connector  blocks  on  the  circuit  board  at 
the rear side plugs into the system backplane of 
the system housing. More information is avail-
able  in  the  NYCe 4000  Hardware  System 
Manual. 

10  Installation and Removal 

______________________________________ 

    

Damage to components 

may occur if power is applied during instal-
lation or removal.

 

 

 

Make sure power supplies are switched 
off before installation or removal of the 
system housing. 

 

Do not apply power until the drive mod-
ule is installed. 

______________________________________ 
______________________________________ 

    

Damage to components 

may occur if drive power voltage is too high.

 

 

 

Make sure that the DP drive voltage is 
changed (lowered) before you install the 
NY4125 drive module in a drive slot 
previously configured for an NY4120 or 
NY4140 drive module. 

______________________________________ 
______________________________________ 

    

Damage to components 

may occur due to electrostatic discharges.

 

 

 

Comply with all ESD protective 
measures while working with modules 
and components. Avoid electrostatic dis-
charges. 

______________________________________ 
______________________________________ 

    

Damage to components 

may occur if installed in the wrong system 
housing.

 

 

 

Make sure this drive module is only 
installed in the NYS04.1-ST-03-4125-
NY4063 system housing. 

 

Make sure this drive module is only in-
stalled in drive slot 0, marked “NY4125”. 

______________________________________ 
 

Power  supplies  must  be  switched  on/off 

with  the  disconnecting  device  installed  in  the 
cabinet. 

The  drive  module  may  only  be  used  as 

build-in equipment, which means that the end-
user must provide a suitable fire and electrical 
safe enclosure. 

The  drive  module  may  only  be  used  in 

combination  with  external  approved  power 
supplies.  The  supply  voltages  24V  System, 
24V Dig, and 24V Fdig for the system must be 
separated at least by reinforced insulation from 
all  hazardous  voltages  according  to  the  stand-
ard UL61010-1 third edition. 

 

10.1

 

Mechanical Dimensions 

The  dimensions  of  the  drive  module  are  the 
following: 

 

You can see the dimensions of the drive mod-
ule in the following views. 

 

 

10.2

 

Installation of the Drive Module 

The drive module is intended for installation in 
the 

NY4063 

system 

housing 

with 

Bosch Rexroth backplane. The drive module is 
always  installed  in  the  slot  marked  with  the 
text ‘NY4125’. 

Position  the  drive  module  in  the  front  slot 

guides  and  gently  slide  the  module  into  the 
slot.  Align  the  connectors  of  the  module  with 
the  connectors  on  the  system  backplane.  Then 
push the module into the connector. Do 

not

 use 

excessive  force  to  prevent  damage  to  the  con-
nector pins. 

 

In Betrieb

 

Lagerung und  
Transport  

Max. Um-
gebungs-
temperatur  

+5 ... +55 °C  

-25 °C bis +70 °C  

Relative 
Feuchte  

RH-2; 5 % bis 95 % nach 
DIN EN 61131-2,  Betau-
ung nicht zulässig. 

RH-2; 5 % bis 95 % 
nach DIN EN 61131-2,  
Betauung nicht zulässig. 

Luftdruck  

Bis 2700 m über NN nach 
DIN 60204  

Bis 3000 m über NN 
nach DIN 60204  

Mechani-
sche Fes-
tigkeit  

Max. Vibration:  
Frequenzbereich:  
10...150 Hz   
Auslenkung: 0,075 mm 
bei 10...57 Hz 
Beschleunigung: 1 g 
bei 57...150 Hz 
Nach EN 60068-2-6 

Max. Schock: 15 g nach 
EN 60 068-2-27, keine 
Störung der Funktion 

Typecode

 

Width 

Height 

Depth 

NYM04.1-5PW-NNNN-NY4125 

21.7 
mm 

128.4 
mm 

148.5 
mm 

 

Содержание Rexroth NYM04.1-5PW-NNNN-NY4125

Страница 1: ...d over to another person these Instructions must be handed over as well 1 4 Included Parts 1 5 Variations These Instructions apply to the drive module with the following Type code NYM04 1 5PW NNNN NY4125 1 6 Further Available Documentation 1 7 Additional Parts The specific system housing NYS04 1 ST 03 4125 NY4063 for the NYM04 1 5PW NNNN NY4125 host adapter Motion Control Units fan unit capacitor ...

Страница 2: ... case of non compliance with this safety in struction death or serious injury will occur ______________________________________ ______________________________________ In case of non compliance with this safety in struction death or serious injury can occur ______________________________________ ______________________________________ In case of non compliance with this safety in struction minor or ...

Страница 3: ...claration of Conformity The drive module described in the present in structions comply with the requirements and the target of the following EU directive and with the following harmonized European standards Low Voltage Directive 2006 95 EC This product is a built in unit which owing to its installation characteristics is not able to comply with the regulations for complete appa ratus machines or i...

Страница 4: ...ing Make sure this drive module is only installed in the NYS04 1 ST 03 4125 NY4063 system housing Make sure this drive module is only in stalled in drive slot 0 marked NY4125 ______________________________________ Power supplies must be switched on off with the disconnecting device installed in the cabinet The drive module may only be used as build in equipment which means that the end user must p...

Страница 5: ...odule The flash memory on the MCU also contains a bootloader to communi cate with the NYCe 4000 tools such as NYCe Configurator With the tools you can download from the PC to the MCU the required firmware for the MCU and the required gateware for the drive modules installed in the system housing 12 Description of the Drive Module The drive module has two blocks of connectors at the rear edge of th...

Страница 6: ...c materials electronic components and modules Recycling Due to their high content of metal most of the product components can be recy cled In order to recycle the metal in the best possible way it is necessary to disas semble the products into individual mod ules The metals contained in the electric and electronic modules can also be recy cled by means of specific separation pro cesses The synthet...

Страница 7: ...R911336855 04_BAL_DOC January 18 2016 Page 7 of 7 Notes ...