![Bosch rexroth MSK 030 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/bosch/rexroth-msk-030/rexroth-msk-030_operating-instructions-manual_43027017.webp)
2
Safety instructions
2.1
About this product
Observe the general safety notes in this chapter and the safety instructions in
this documentation. Therewith, you avoid personal danger, damage and er‐
rors.
This operating instruction must be stored and transferred in case
of sale during the complete product lifetime.
2.2
Indented use
Prerequisites for proper and safe use of the motors are proper transport, ap‐
propriate storage, proper assembly and connection, careful maintenance, op‐
eration and overhaul.
The motors have been designed for installation in industrial machinery. The
motors are according to the following standards and directives.
Standards
EN 60034-1
Rating and performance behavior
EN 60034-5
Type of protection
Directives
2006/95/EG
Low Voltage Directive (valid until April 19, 2016)
2014/35/EU
Low Voltage Directive 2014/35/EU (valid from April 20, 2016)
The machine manufacturer must evaluate the electric and mechanic safety
as well as environmental influences in the assembled state of the machine
according to the Machine Directive 2006/42/EC and DIN EN 60204-1 (safety
of machines).
The electrical installation must comply with the protection requirements of
EMC Directive 2014/30/EU. The plant manufacturer is responsible for appro‐
priate installation (for example: physical separation of signal and power ca‐
bles, using shielded cables, ...). The EMC instructions of the converter manu‐
facturer must be observed.
The machine may not be commissioned before conformity with these direc‐
tives has been confirmed.
2.3
Unintendend use
Any use of the MSK motors outside of the specified fields of application or
under operating conditions and technical data other than those specified in
this documentation is considered to be "inappropriate use".
Unless explicitly provided for this purpose, the motors may not be used in ex‐
plosion-hazardous areas (compare housing design -NSNN).
Direct operation on the three-phase network is forbidden.
2.4
Qualification of personnel
For the purpose of this manual, qualified personnel means persons who are
familiar with transporting, installing, mounting, commissioning and operating
the components of the electrical drive and control system and the associated
hazards and have an appropriate qualification for their job.
MSK Synchronous Servomotors
3/57
Safety instructions
R911325169_Edition 03 Bosch Rexroth AG
Содержание rexroth MSK 030
Страница 1: ...MSK Synchronous Servomotors Operating Instructions R911325169 Edition 03 ...
Страница 20: ...6 57 MSK Synchronous Servomotors Bosch Rexroth AG R911325169_Edition 03 ...
Страница 22: ...8 57 MSK Synchronous Servomotors Bosch Rexroth AG R911325169_Edition 03 ...
Страница 32: ...18 57 MSK Synchronous Servomotors Bosch Rexroth AG R911325169_Edition 03 ...
Страница 69: ...Notes MSK Synchronous Servomotors 55 57 ...
Страница 70: ...Notes 56 57 MSK Synchronous Servomotors ...
Страница 71: ...Notes MSK Synchronous Servomotors 57 57 ...