22 / 50
MS2S
Features and functions
Bosch Rexroth AG
R911410077, Edition 01
5.2.2
Mechanical interfaces
Dimensions (flange)
ØG
ØC
A
B
D
E
ØF
Type
A
☐
Flange
[mm]
B
Length
[mm]
C
Shaft
Ø
[mm]
D
Shaft length
[mm]
E
Centering
collar [mm]
F
Hole circle
[mm]
G
Mounting
holes [mm]
MS2S03
58
1)
9
20
40
63
4.5
MS2S04
82
1)
14
30
50
95
6.6
MS2S05
98
1)
19
40
95
115
9
1) See dimensions
Use the following screws and washers for flange assembly.
Screws according to DIN
EN
ISO
4762 or DIN
EN
ISO
4014. Property class 8.8 The screw lengths
depends on material and installation situation. The specified tightening torque must be ensured.
Table 6: Tightening torque of mounting screws
Screw
M4
M6
M8
Mounting holes
⌀
[mm]
4.5
6.6
9
Tightening torque M
A
[Nm] at
μ
K
= 0.12
3.0
10.1 24.6
Washer
-
-
yes
5.2.3
Thermal motor protection
The motor temperature is monitored via a sensor-
based, drive-internal temperature model and
ensures a high level of protection for the motors
against thermal overload.
The threshold values for motor temperature mon-
itoring are contained in the encoder data memory
and are read in and monitored automatically
during the operation with Rexroth controllers.
Threshold values for MS2S motors are:
•
Motor-warning temperature (140°C)
•
Motor-disconnection temperature (145°C)
5.2.4
Cooling mode
Self-cooling (IC410)
In case of self-cooling motors, the heat dissipa-
tion is realized via natural convection and radia-
tion to the ambient air as well as by heat conduc-
tion to the machine construction.
The specified nominal data is reached at ambient
temperatures of up to 40 °C. Unhindered vertical
convection has to be ensured by a sufficient dis-
tance of 100 mm to adjacent components. Any
usage at increased ambient temperature (0 ...
60°C) is possible. Please note the details in
Chapter 8.5 “Derating in case of deviating