IPC 40.2
Connections
7-13
DOK-SUPPL*-IPC*40.2***-PR02-EN-P
4
2
(green/yellow)
PE
U1
V1
W1
N
PE
PE
N1
16
2
Min.16
2
To control cabinet housing
400V
230V
4
2
(green/yellow)
PE
N1
U2
4
2
16
2
To machine
6
2
All housing components (PE bolt)
Don't use the neutral
conductor "N"
without permission
of the operator!
PE
10
2
PE terminal bar for 0 V wiring
(see fig. 2)
: Terminals in isolated configuration
PE
PE
PE
PE
PE
Transformer as per
EN 60742
Fuses; motor protection key preferred
L1.1
L2.1
L3.1
N
230 V supply
operator terminals
service plug receptacles
U2
E.g., drives
Incoming mains
PE star point
Overvoltage
category III
Overvoltage
category II
L1
L2
L3
N
(green/yellow)
(green/yellow)
(green/yellow)
(green/yellow)
(green/yellow)
(green/yellow)
trenntrafo.cdr
Fig. 7-17:
Voltage connection 230 VAC via isolating transformer
Battery Connection
Connection terminal for an external battery for the integrated UPS:
2-pin
Cable length
Max. 3.0 m
Cable type
Unshielded, cross section 1.5 mm²
Battery connection X19
Akku_Anschluss.FH9
Fig. 7-18:
Battery connection
X19 Battery Connection
Содержание Rexroth IPC 40.2
Страница 6: ...IV Contents IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P ...
Страница 20: ...3 10 Safety Instructions for Electric Drives and Controls IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P Notes ...
Страница 26: ...4 6 Technical Data IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P ...
Страница 54: ...8 10 Maintenance and Installation IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P ...
Страница 74: ...12 4 Index IPC 40 2 DOK SUPPL IPC 40 2 PR02 EN P ...
Страница 81: ......