9.3
Analog inputs/outputs: Shield connection
9.3.1
Analog input
A
Analog input of the drive controller; only connect the inner
shield of the connection cable to the drive controller if GND has
not been connected to ground in the external device.
B
External device
IS
Inner shield of the connection cable
OS
Overall shield of the connection cable
Fig. 9-1:
Shield connection for analog inputs
9.3.2
Analog output
A
Analog output of drive controller
B
External device; only connect the inner shield of the connection
cable to the external device if GND has not been connected to
ground in the external device.
IS
Inner shield of the connection cable
OS
Overall shield of the connection cable
Fig. 9-2:
Shield connection for analog outputs