If there is no supply voltage of 24 V, the operator display immediately
darkens. The user cannot execute any actions via the operator display
during the shutdown of the control cabinet PC.
3. DIS function
The operation at the VDP as well as all USB end devices connected at
the VDP via XUSB1 up to XUSB4 or connected to the front USB port
are disabled.
X10
Control cabinet PC
UPS
24V
24V
Out
24V
In
230V~
+
-
+
-
U
+
-
+
-
1
2
3
USB port
type B
USP port
Type A
USB cable
X1S1/2 (GND)
X1S1/1 (DC 24 V)
Operating display
XUSB1...4
Front
USB port
(optional)
CDI, CDI+
External
30 V
24 V
power supply
Fig. 7-4:
Voltage supply
7.1.4
XUSB Interfaces
The devices feature four USB interfaces on the connector panel (XUSB1/2
and XUSB3/4), and, depending on the version, one interface on the front
panel.
USB devices (e.g. keyboard) switch off if the power consumption
of all USB connectors exceeds 1 A.
The maximum power consumption of one USB connector must
not exceed 500 mA. The total current of all USB connectors must
not exceed 1 A. The voltage supply of other VDP function units
are not impaired by the switched-off USB voltage.
●
The USB devices are enabled as soon as the total current is
below 1 A (time delay approx. 30 seconds) or as soon as the
power consumption of one connector is below 500 mA.
●
In the taskbar no message is displayed that the USB devices
are disabled.
Fig. 7-5:
USB interfaces XUSB1/2 and XUSB3/4
CDI: Operating the USB connections on the VDP 16.3/40.3 in USB2.0 mode
The USB connections on the VDP 16.3/40.3/60.3 only support USB1.1
because the data is transferred to the control cabinet PC by using the XSER
interface. If USB2.0 is required on the VDP 16.3/40.3/60.3, it can be
implemented by connecting the XUSBIN connection to the
38/57
Interfaces
IndraControl VDP 16.3, VDP 40.3, VDP 60.3 Operator Dis‐
play
Bosch Rexroth AG R911323862_Edition 07
Содержание Rexroth IndraControl VDP 40.3
Страница 6: ...IV IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 12: ...6 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 22: ...16 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 40: ...34 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 48: ...42 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 60: ...54 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 63: ...Notes IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Display 57 57 ...