9.2 Overview
Name at the
housing
Connection type
Connector type, inte-
grated
Mating connector or
cable (from outside)
①
S1
Refer to
chapter 9.4 "S1 DIP switch" on page 14
②
XVID
CDI interface, image
RJ45 socket
RJ45 plug
③
XSER
CDI interface, data
RJ45 socket
RJ45 plug
④
XUSB1/2
2 USB interfaces
USB socket,
4-pin, type A
USB plug,
4-pin, type A
⑤
XUSBIN
USB2.0 connection to the control
cabinet PC. Maximum length 5 m
Use only one high-speed USB 2.0
cable (refer to
necting cables for the USB inter-
USB socket,
4-pin, type B
USB plug,
4-pin, type B
⑥
X1S1
24 V DC voltage supply
3-pin, MC1,5/3-
G-3,5 THT
3-pin, FK-MCP 1,5/3-
ST-3,5
⑦
Functional earth (FE)
M5
Ring cable lug
Tab. 9-1: Interfaces
Malfunctions due to insufficient shielding!
NOTICE
Use only shielded cables and metallic or conductive connector/coupling covers
with large-area shield support.
9.3 24 V DC voltage supply
Fig. 9-2: Interface for 24 V voltage supply
Pin
Function
1
+24 V supply voltage
2
0 V supply voltage
3
n.c.