Destruction of the device due to improper
connection
NOTICE
If connected improperly, the device might be destroyed. For that reason,
avoid:
●
Polarity reversal with simultaneous short-circuit of the output lines.
●
Polarity reversal with simultaneous connection of externally polarized
suppressor diodes.
●
Applying an external voltage at the digital output which is greater than
the segment voltage U
S
.
If the 2-pin connection is incorrect, there is no
longer protection from GND breakage.
NOTICE
The 0 V reference of the connected loads must be returned to the 0 V con‐
nection of the control. I.e. a two-pin connection must be ensured. Otherwise,
there will be no reliable protection from GND breakage.
10.7.11 Further Interfaces
The further interfaces (Ethernet, PROFIBUS DP, sercos, Ready contact,
Compact Flash card, Inline bus and function modules) are described in the
project planning manuals of the Rexroth IndraControl L45/L65/L85 and
Rexroth IndraControl L25 controls, see also
.
Connect the Ready contact (X2R) by means of cables featuring a
conductor cross-section of AWG 16-24.
Bosch Rexroth AG
DOK-CONTRL-IC*LX5*****-IT01-EN-P
Rexroth IndraControl L25, L45, L65 and L85 Controls
46/65
Mounting, Dismounting and Electrical Installation
Содержание Rexroth IndraControl L25
Страница 6: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls IV 65 ...
Страница 10: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls 8 65 ...
Страница 12: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls 10 65 ...
Страница 14: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls 12 65 ...
Страница 26: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls 24 65 ...
Страница 50: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls 48 65 ...
Страница 54: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls 52 65 ...
Страница 62: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls 60 65 ...
Страница 64: ...Bosch Rexroth AG DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls 62 65 ...
Страница 67: ...Notes DOK CONTRL IC LX5 IT01 EN P Rexroth IndraControl L25 L45 L65 and L85 Controls Bosch Rexroth AG 65 65 ...