Commissioning

• Before commissioning, check that all 

plug-in connections have the correct seat.

• Once the system has been switched on 

and the module has been initialized, it is 
then ready for communication on the 
network and waits to be connected by the 
Ethernet IP scanner.

• The NS LED and MS LED run through a 

test sequence following system boot up. 

• The ESD file (device master data) 

corresponding to the interface module 
can be created with the BS350 operating 
software.

8

Operation

Operation is not necessary while the system 
is running.

9

Maintenance and 
repair

Cleaning and care

Maintenance

The IMenip interface module is maintenance-
free if used as intended.

Spare parts

Please refer to the address directory under 
www.boschrexroth.com and in chapter 
“16 Service and sales” on page 26 for the 
addresses of our foreign subsidiaries. 

10

Decommissioning

For details about how to disassemble or 
replace your IMenip interface module please 
refer to chapter “11 Disassembly and 
replacement” on page 23.

CAUTION

Risk of damage to persons 
and property!

Commissioning of the IMenip 
interface module requires basic 
mechanical and electrical 
knowledge.

y

Only qualified personnel (see 
“Personnel qualifications” on 
page 16) are authorized to 
commission the system.

CAUTION

Any dirt or liquids penetrating 
the device lead to 
malfunctions!

Safe function of the IMenip 
interface module is no longer 
ensured.

y

Always provide for absolute 
cleanness when working on 
the IMenip interface module.

Содержание Rexroth IMenip

Страница 1: ...NS MS LINK EtherNet IP IMenip 3 609 929 B63 2008 09 ...

Страница 2: ...ata 25 Service and sales 26 The data specified above only serve to describe the product No statements concerning a certain condition or suitability for a certain application can be derived from our information The information given does not release the user from the obligation of own judgment and verification It must be remembered that our products are subject to a natural process of wear and agin...

Страница 3: ...es Always include the operating instructions when you pass the IMenip interface module on to third parties Intended use The IMenip interface module is a component in terms of the machine directive 98 37 EC and is not a ready for use machine The product is exclusively intended for being integrated in a machine or system or for being assembled with other components to form a machine or system The pr...

Страница 4: ...the following instructions General safety instructions Only accessories and add on units that have been approved for use in Rexroth tightening systems may be used therein Non approved components may neither be added nor connected to the system The same applies to cables and lines which belong to the Rexroth tightening system Otherwise functional and system safety is jeopardized Observe the regulat...

Страница 5: ...hat all the plug connectors are installed correctly undamaged and that all screws are tightened During commissioning Let the product acclimate itself for several hours before commissioning otherwise water may condense in the housing Make sure that all electrical connections are either used or covered Commission the product only if it is installed completely During cleaning Cover all openings with ...

Страница 6: ... indicates the connection or activity via Ethernet Table 1 Pin Signal Description function 1 Transmit Ethernet transmission cable 2 Transmit Ethernet transmission cable 3 Receive Ethernet reception cable 4 NC 5 NC 6 Receive Ethernet reception cable 7 NC 8 NC 4 1 3 2 5 NS MS LINK Table 2 NS LED display Meaning Off No voltage not initialized or invalid IP address Green Online one or more connections...

Страница 7: ...er in idle mode Red Error exception error or blocking error Flashing red Self acknowledged error CAUTION Risk of damage to persons and property Assembly of the IMenip interface module requires basic mechanical and electrical knowledge y Only qualified personnel see Personnel qualifications on page 16 are authorized to assemble the IMenip interface module y Measures to prevent electrostatic dischar...

Страница 8: ...rface module 2 Insert the IMenip interface module into the appropriate slot on the system component until it catches example in Fig 2 3 Tighten the torx screws on the front until the front panel is flush The circuit board is locked by turning the screw This lock is only fully functional once the interface has been properly tightened see Fig 3 Fig 2 Example Inserting the interface module Fig 3 Lock...

Страница 9: ...face module is maintenance free if used as intended Spare parts Please refer to the address directory under www boschrexroth com and in chapter 16 Service and sales on page 26 for the addresses of our foreign subsidiaries 10 Decommissioning For details about how to disassemble or replace your IMenip interface module please refer to chapter 11 Disassembly and replacement on page 23 CAUTION Risk of ...

Страница 10: ...evant system components are not under voltage 2 Loosen the front torx screws The IMenip interface module may only be removed once the lock has been completely released see Fig 4 3 Assemble a dummy panel if necessary Fig 4 Releasing the lock 1 Lock CAUTION Disconnecting the IMenip interface module while under voltage Damage to the IMenip interface module y Always switch off the power supply to the ...

Страница 11: ...ctions and information on errors are displayed in the tightening system e g in the BS350 The NS LED indicates the Ethernet status The MS LED indicates the interface module status If you should not be able to remedy an occurring defect please contact one of the addresses that you can find under www boschrexroth com or in the address directory in chapter 16 Service and sales on page 26 Table 5 NS LE...

Страница 12: ... 271 Dimensions width x height x depth 50 1 x 22 3 x 56 8 mm Weight 30 g Operating temperature range Designed for operation in System 350 components Storage temperature range 20 C to 70 C Permissible humidity for application 20 90 non condensing Permissible humidity for storage 20 95 Protection class in acc with EN 60529 IEC529 IP 20 NEMA 1 when installed Mounting orientation Any ...

Отзывы: