Only use the product within the performance 
range provided in the technical data.

Persons who assemble, operate, 
disassemble or maintain Rexroth products 
must not consume any alcohol, drugs or 
pharmaceuticals that may affect their ability 
to respond.

The warranty only applies to the delivered 
configuration. 

The warranty will not apply if the product is 
incorrectly assembled or handled or not used 
as intended.

Do not expose the product to any mechanical 
loads under any circumstances. Do not place 
any objects on it.

During assembly

Make sure the relevant system component is 
not under pressure or voltage before 
assembling the product or when connecting 
and disconnecting plugs. Protect the system 
against being switched on.

Lay cables and lines so that they cannot be 
damaged, are in accordance with the 
bending radiuses, and no one can trip over 
them.

Before commissioning, make sure that all the 
plug connectors are installed correctly, 
undamaged, and that all screws are 
tightened.

During commissioning

Let the product acclimate itself for several 
hours before commissioning, otherwise 
water may condense in the housing.

Make sure that all electrical connections are 
either used or covered. Commission the 
product only if it is installed completely.

During cleaning

Cover all openings with the appropriate 
protective equipment in order to prevent 
detergents from penetrating the system.

Never use solvents or aggressive detergents. 
Only clean the product using a slightly damp, 
lint-free cloth. Only use water to do this and, 
if necessary, a mild detergent.

Disposal

Dispose of the product in accordance with 
the currently applicable national regulations 
in your country.

3

Delivery contents

The delivery contents include:

• 1 IMenip interface module 

• 1 instruction manual for the IMenip 

interface module 

4

Product description

Performance description

A tightening system is controlled by this 
interface. It can transfer cyclic I/O data.

The IMenip interface module is directly 
supplied with power via the components in 
the System 350.  

Содержание Rexroth IMenip

Страница 1: ...NS MS LINK EtherNet IP IMenip 3 609 929 B63 2008 09 ...

Страница 2: ...ata 25 Service and sales 26 The data specified above only serve to describe the product No statements concerning a certain condition or suitability for a certain application can be derived from our information The information given does not release the user from the obligation of own judgment and verification It must be remembered that our products are subject to a natural process of wear and agin...

Страница 3: ...es Always include the operating instructions when you pass the IMenip interface module on to third parties Intended use The IMenip interface module is a component in terms of the machine directive 98 37 EC and is not a ready for use machine The product is exclusively intended for being integrated in a machine or system or for being assembled with other components to form a machine or system The pr...

Страница 4: ...the following instructions General safety instructions Only accessories and add on units that have been approved for use in Rexroth tightening systems may be used therein Non approved components may neither be added nor connected to the system The same applies to cables and lines which belong to the Rexroth tightening system Otherwise functional and system safety is jeopardized Observe the regulat...

Страница 5: ...hat all the plug connectors are installed correctly undamaged and that all screws are tightened During commissioning Let the product acclimate itself for several hours before commissioning otherwise water may condense in the housing Make sure that all electrical connections are either used or covered Commission the product only if it is installed completely During cleaning Cover all openings with ...

Страница 6: ... indicates the connection or activity via Ethernet Table 1 Pin Signal Description function 1 Transmit Ethernet transmission cable 2 Transmit Ethernet transmission cable 3 Receive Ethernet reception cable 4 NC 5 NC 6 Receive Ethernet reception cable 7 NC 8 NC 4 1 3 2 5 NS MS LINK Table 2 NS LED display Meaning Off No voltage not initialized or invalid IP address Green Online one or more connections...

Страница 7: ...er in idle mode Red Error exception error or blocking error Flashing red Self acknowledged error CAUTION Risk of damage to persons and property Assembly of the IMenip interface module requires basic mechanical and electrical knowledge y Only qualified personnel see Personnel qualifications on page 16 are authorized to assemble the IMenip interface module y Measures to prevent electrostatic dischar...

Страница 8: ...rface module 2 Insert the IMenip interface module into the appropriate slot on the system component until it catches example in Fig 2 3 Tighten the torx screws on the front until the front panel is flush The circuit board is locked by turning the screw This lock is only fully functional once the interface has been properly tightened see Fig 3 Fig 2 Example Inserting the interface module Fig 3 Lock...

Страница 9: ...face module is maintenance free if used as intended Spare parts Please refer to the address directory under www boschrexroth com and in chapter 16 Service and sales on page 26 for the addresses of our foreign subsidiaries 10 Decommissioning For details about how to disassemble or replace your IMenip interface module please refer to chapter 11 Disassembly and replacement on page 23 CAUTION Risk of ...

Страница 10: ...evant system components are not under voltage 2 Loosen the front torx screws The IMenip interface module may only be removed once the lock has been completely released see Fig 4 3 Assemble a dummy panel if necessary Fig 4 Releasing the lock 1 Lock CAUTION Disconnecting the IMenip interface module while under voltage Damage to the IMenip interface module y Always switch off the power supply to the ...

Страница 11: ...ctions and information on errors are displayed in the tightening system e g in the BS350 The NS LED indicates the Ethernet status The MS LED indicates the interface module status If you should not be able to remedy an occurring defect please contact one of the addresses that you can find under www boschrexroth com or in the address directory in chapter 16 Service and sales on page 26 Table 5 NS LE...

Страница 12: ... 271 Dimensions width x height x depth 50 1 x 22 3 x 56 8 mm Weight 30 g Operating temperature range Designed for operation in System 350 components Storage temperature range 20 C to 70 C Permissible humidity for application 20 90 non condensing Permissible humidity for storage 20 95 Protection class in acc with EN 60529 IEC529 IP 20 NEMA 1 when installed Mounting orientation Any ...

Отзывы: