20
/76
Bosch Rexroth AG
IMenip | 3 609 929 B63/2008-09
The MS LED indicates the interface module
status.
5
Transport and storage
For storing and transporting the product
always observe the ambient conditions
specified in the technical data (see
“Technical data” on page 25).
6
Assembly
When installing the product always observe
the ambient conditions specified in the
technical data (see “Technical data” on
page 25).
Required tools
• TX9 screwdriver
Assembling the IMenip interface
module
Table 4 MS
LED display
Meaning
Off
No voltage or not initialized
Green
Module controlled by a scanner
during operation
Flashing
green
Not configured or scanner in idle
mode
Red
Error (exception error or blocking
error)
Flashing red
Self-acknowledged error
CAUTION
Risk of damage to persons
and property!
Assembly of the IMenip interface
module requires basic mechanical
and electrical knowledge.
y
Only qualified personnel (see
“Personnel qualifications” on
page 16) are authorized to
assemble the IMenip interface
module.
y
Measures to prevent
electrostatic discharge (ESD
protection) must be
undertaken to protect the
module and system
components during all
assembly work.
CAUTION
Risk of injuries when
assembling under voltage!
If you do not switch off the power
supply before assembling the
IMenip interface module, you may
get injured or the device or system
components may be damaged.
y
Always switch off the power
supply to the relevant system
component before assembling
the IMenip interface module.