CS351_zweispaltig - D.book Seite 88 Donnerstag, 2. Oktober 2014 8:36 08
CS351/CC-CS351
| 3 609 929 B45/2019-12
78
/
96
Bosch Rexroth AG
7.
7. Assemble the front cover.
8.
8. Close and lock the front cover.
9.
9. Connect the hand-held nutrunner/tightening
spindle:
10.
10.
10. Connect the power supply connection cable.
The user is responsible for complying with
the regulations for the power supply
connection.
11.
11.
11. Switch the Compact System on at the power
switch.
Operation
8
Operation
CAUTION
Disconnection of plug connectors that are
carrying voltage!
Damage to the Compact System
Always switch the system off at the main
switch and then disconnect the power
supply connection cable. Wait until the
discharging time (at least 90 seconds) has
elapsed.
CAUTION
Contamination of the Compact System!
Injuries and damage to property
Only operate the Compact System
with the front cover closed.
CAUTION
Hot surfaces!
Injuries
The metal surfaces of the housing may have
a temperature of up to 70 °C during
operation.
NOTE
Important operation information
Keep the air ways used for cooling the
Compact System clear.