Troubleshooting 53/60
RE 92701-01-B/04.2018, A10VO, A10VSO Series 31,
Bosch Rexroth AG
14.2 Malfunction table
Table 14: Axial piston unit malfunction table
Malfunction
Possible cause
Remedy
Unusual noises
Insufficient air bleeding of the hydraulic system
Fill the axial piston unit, suction line for the
hydraulic pump and the reservoir
Completely air bleed the axial piston unit and
hydraulic system
Check correct installation position
Insufficient suction conditions, for example,
insufficient dimensioning of the suction line,
viscosity of the hydraulic fluid too high,
suction height too high, suction pressure
too low, foreign particles in the suction line,
impermissible filter in the suction line
Machine/system manufacturer: check the
system, for example, optimize inlet conditions,
use suitable hydraulic fluid
Fill the suction line with hydraulic fluid
Remove foreign particles from the suction line
Drive speed too high
Machine/system manufacturer: Reduce drive
speed
Wrong direction of rotation
Machine/system manufacturer: Check correct
direction of rotation; see chapter 7.4.1
“Preparation” on page 31
Improper mounting of the axial piston unit
Check the mounting of the axial piston unit
according to the specifications of the machine/
system manufacturer – observe tightening
torques
Improper mounting of assembled parts,
hydraulic lines or improper installation of the
coupling
Mount assembled parts according to the
information provided by the coupling fitting
manufacturer
Valve and controller vibrations
Optimize the adjustment of the axial piston
unit and the pressure limitation in the hydraulic
system
Mechanical damage to the axial piston unit
(e.g. bearing damage)
Replace axial piston unit
Contact Bosch Rexroth Service
Increased, unusual vibration
Bearings worn
Contact Bosch Rexroth Service