Overvoltage category: II.
Maximum altitude: 4000 m.
17.5
Derating Conditions
17.5.1
Introduction
The NYCe 4000 system can be used as a convection cooled system.
However, this will limit the maximum current to the motors because of the
heat dissipation in the drive modules. In a practical situation not all motors
need high power and do not need full power at the same moment. Since
forced cooled systems are not always possible, the graphs give more insight
in the possibilities of convection cooled systems at a given environmental
temperature.
The NY4053 system housing is used during the measurements, except for
the measurements of the NY4125 drive module. The NY4063 system
housing is used during the measurements of the NY4125. Other drive
modules and system housings will have similar characteristics.
17.5.2
Forced cooled systems, NY4120
The NYCe 4000 system can be installed with a standard fan unit with 3 fans
each producing an airflow of 11.3 m
3
/hr. The fan unit is strongly advised if
motors are used with motor currents higher than 2 A rms and/or the
environmental temperature is higher than 35 °C in a full system configuration.
When five NY4120 drive modules are used in the NY4053 system housing,
you can build the maximum configuration with 10 axes.
current for 10 axes (5 NY4120 drive modules) and all digital outputs at 1 A
load with 3 fans (airflow 11.3 m
/hr) installed vs. environmental temperature"
shows the situation when all 10 motors ask continuously the
same motor current and all 20 digital outputs are driving a load of 1 A
continuously. Under these conditions the maximum motor current is 7 A rms
at an environmental temperature of up to 48 °C. Measurements indicate that
7 A rms is also possible up to the maximum supported environmental
temperature of 55 °C, if fans are used producing an airflow of 20 m
3
/hr.
70
20
30
40
10
0
50
60
Environmental temperature (°C)
Motor
current
(A. rms)
2
4
6
8
0
Fig. 17-1:
Max. motor current for 10 axes (5 NY4120 drive modules) and all
digital outputs at 1 A load with 3 fans (airflow 11.3 m
3
/hr) installed vs.
environmental temperature
218/233
Environmental Conditions
NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual
Bosch Rexroth AG R911337671_Edition 18
Содержание R911172904
Страница 109: ...100 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 133: ...124 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 165: ...156 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 213: ...204 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 235: ...226 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 239: ...230 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 242: ...Notes NYCe 4000 Multi axis motion control system Hardware Sys tem Manual 233 233 ...