+/- 10 Volt Differential
See Note 5 and 6
AnIn
+
AnIn
-
AnVref
+/- 10 Volt Single ended
Application
ground
AnIn
+
AnIn
-
See Note 7
AnVref
Node
Node
Appplication
Appplication
AnGND
AnGND
Fig. 10-6:
Connection methods
10.8
Analog Outputs
Characteristic
Description
Number of analog outputs
2: AnOut0 and AnOut1 with common AnGND
Type
Single ended; no galvanic insulation
Functions
External power amplifier control
General Purpose analog output
Grounding
Both analog output signals refer to AnGND, see
note 1
Range
–10 V …+10V
Resolution
16 bit, monotonic (DAC8532)
Accuracy
Absolute: 3% of full scale
Relative: 0.1% of full scale
Offset
Typical 30 mV, max. 120 mV
Noise
0.55 mV rms
Maximum output current
10 mA
Range load resistor
(R2 in figure below)
≥ 1 kΩ
Capacitive load
(C2 in figure below)
≤ 10 nF
Output short circuit proof
Yes, Ishort ≤ 35mA
Bandwidth DAC
4 kHz
Update frequency
Maximum 32 kHz
Tab. 10-6:
Characteristics of the analog outputs
108/233
NY4130: DC Drive Module
NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual
Bosch Rexroth AG R911337671_Edition 18
Содержание R911172904
Страница 109: ...100 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 133: ...124 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 165: ...156 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 213: ...204 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 235: ...226 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 239: ...230 233 NYCe 4000 Multi axis motion control system Hardware Sys tem Manual Bosch Rexroth AG R911337671_Edition 18 ...
Страница 242: ...Notes NYCe 4000 Multi axis motion control system Hardware Sys tem Manual 233 233 ...