English |
13
Bosch Power Tools
1 609 92A 0K5 | (11.4.14)
Assembly
Inserting/Replacing the Batteries
Using alkali-manganese or rechargeable batteries is recom-
mended for operation of the measuring tool.
To open the battery lid
5
, press on the latch
6
and fold the bat-
tery lid up. Insert the batteries/rechargeable batteries. When
inserting, pay attention to the correct polarity according to
the representation on the inside of the battery lid.
The battery low indicator
p
indicates when the batteries/re-
chargeable batteries become empty:
–
max. 30 % battery power,
–
max. 10 % battery power.
When the battery low indicator
p
flashes, the batteries/re-
chargeable batteries must be replaced. Measurements are no
longer possible.
Always replace all batteries/rechargeable batteries at the
same time. Do not use different brands or types of batter-
ies/rechargeable batteries together.
Remove the batteries/rechargeable batteries from the
measuring tool when not using it for longer periods.
When storing for longer periods, the batteries/rechargea-
ble batteries can corrode and self-discharge.
Operation
Initial Operation
Protect the measuring tool against moisture and direct
sun light.
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature.
As an example, do
not leave it in vehicles for a long time. In case of large vari-
ations in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool can be impaired.
Ensure that the measuring tool is correctly acclima-
tized.
In case of large variations in temperature, acclima-
tization can take up to 30 minutes. This may be the case,
for example, if you first perform a measurement in the cool
cellar and then go up to the warm attic.
Avoid heavy impact to or falling down of the measuring
tool.
Do not shut or cover off the humidity and temperature
sensor 1, the reception lens 2 and the laser beam exit
opening 3.
Switching On and Off
For
switching on
the measuring tool, the following possibili-
ties are given:
– Switch the measuring tool on with the
On/Off button
13
.
After a short start-up sequence, the measuring tool is
ready for operation with the settings (operating mode,
Laser class
2
Laser type (typically)
635 nm, <1 mW
Batteries
Rechargeable batteries
2 x 1,5 V LR06 (AA)
2 x 1,2 V HR06 (AA)
Operating time, approx.
9 h
Weight according to EPTA-Procedure 01/2003
0.3 kg
Dimensions (length x width x height)
124 x 53 x 180 mm
Thermo detector
PTD 1
The measuring tool can be clearly identified with the serial number
17
on the type plate.
1) At a measuring distance of 0.75 –1.25 m to the surface
2) At an ambient temperature of 22 °C
3) Information according to VDI/VDE 3511 Page 4.3 (publication date: July 2005); applies for 90 % of the measuring signal.
Deviations of the measuring results are possible in all ranges beyond the indicated dimensions in the Technical Data.
4) Refers to infrared measurement, see graphic:
1,
7 cm
10 cm
0,17 m
1 m
OBJ_DOKU-31220-002.fm Page 13 Friday, April 11, 2014 10:35 AM