background image

4

Clearances

A range hood fitted above the top must be installed according 

to the installation instructions for the range hood. A minimum 

distance of 650 mm is required for a range hood and 750 mm 

for an exhaust fan.
Any adjoining wall surface situated within 200 mm from the 

edge of any hob burner must be a suitable non-combustible 

material for a height of 150 mm for the entire length of the hob. 

Any combustible construction above the hotplate must be at 

least 650 mm above the top of the burner and no construction 

shall be within 450 mm above the top of the burner.

A minimum depth of 50 mm from the top of the worktop 

surface must be provided for the appliance. 
If the base of the hotplate can be touched, a protecting shield 

must be fitted.

The shield must be at least 10 mm from the lowest part of the 

hotplate and must be capable of withstanding the appliance 

temperatures. Minimum thickness of benchtop is 30 mm.

The shield material must be mdf or similar with minimum 

thickness of 12 mm.

The shield overall dimensions must be 560 mm wide x 

480 mm deep.

Provide cut-out in right hand rear of shield of 80 mm wide x 

80 mm deep to provide for gas regulator / LP connection 

fitting.

After installation of the shield the clearance around the top and 

sides of shield will allow adequate ventilation. Ensure the side 

and top clearances are not obstructed.

If an oven is positioned below the cooktop the barrier does not 

need to be fitted, but a space of 35 mm must be maintained 

between the underside of the cooktop and the top of the oven.
A space of 5 mm must be mantained between the benchtop 

and the top front part of the oven.

Installation of cooktop into the kitchen bench

Side clearances: If the distance measured from the periphery of 

the nearest burner to any vertical surface is less than 200 mm, 

the surface shall be protected in accordance with clauses 

6.10.1.2 of AS/NZS 5601.1.

For cutout dimensions and clearances see 

Preparing to install

.

Installation procedure:
The clips and the adhesive seal (underside of the cooktop) are 

already fitted (depending on the model), do not under any 

circumstances remove them. The seal ensures that the entire 

work surface will be watertight, and prevents water seepage.
Fitting the appliance onto the kitchen unit:

1.

Place the cooktop in the correct position then loosen each of 

the clips so that they all turn freely (it is not necessary to 

completely undo them).

2.

Insert and centre the cooktop.
Press the sides of the cooktop until it is supported around its 

entire perimeter.

3.

Turn the clips and tighten them fully.

The position of the clips depends on how thick the work 
surface is.

Connection

Electrical

An electrical 10 amp socket needs to be within 1 m of the 

hotplate to allow electrical connection. The socket must remain 

accessible after installation of the appliance.
Important notes:

This appliance is connected to the mains (240 VAC) by 

means of the connecting lead which must be fixed to the 

kitchen unit to prevent it from coming into contact with hot 

parts of the cooktop (or an oven installed underneath) and 

remain accessible after installation of the cooktop.
When making this connection make sure that the lead cannot 

come into contact with hot parts of the cooktop.

This appliance must be earthed. When connecting the 

cooktop ensure that the earth wire is connected first and that 

all wires are connected to the correct terminals.

PLQ

PLQ

PLQ

PD[

PLQ

PLQ

PLQ

PLQ

PD[

/

9

9

1

99 a

Содержание PBH615B9TA

Страница 1: ...USER INSTRUCTIONS INSTALLATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS GMK10047 This cooktop is for use with Natural Gas and Universal LPG Leave this instructions with the owner PBH615B9TA ...

Страница 2: ...entilation Do not obstruct the flow of combustion and ventilation air Cabinets installed above the gas cooktop must have a minimum clearance of 650 mm 24 The gas pressure regulator supplied with the appliance must be installed in line with the gas pipe N G only For pressure testing in excess of 3 5 kPa 1 2 psig the appliance and its individual shutoff valve must be disconnected from the gas supply...

Страница 3: ...ns Preparing to install Refer to AS NZS 5601 1 for piping size details These built in cooktops are intended to be inserted in a benchtop cutout Only an officially authorised technician should connect the appliance Before you begin turn off the gas and electricity supply Before connecting the unit check whether the local connection conditions type of gas are compatible with the unit s setting Obser...

Страница 4: ...part of the oven Installation of cooktop into the kitchen bench Side clearances If the distance measured from the periphery of the nearest burner to any vertical surface is less than 200 mm the surface shall be protected in accordance with clauses 6 10 1 2 of AS NZS 5601 1 For cutout dimensions and clearances see Preparing to install Installation procedure The clips and the adhesive seal underside...

Страница 5: ...rect operation of gas valves burners and ignition Turn gas taps to low flame position and observe stability of the flame for each burner individually and all together Adhere the duplicate data plate to an accessible location near the hotplate When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all check...

Страница 6: ... reverse order to removal It is important that all the seals are refitted to form a seal Never remove the tap spindle In the event of a malfunction change the whole tap Important After finishing stick the sticker indicating the new gas type close to the specifications plate Operating instructions Burner locations 1 Pan supports 2 Control knobs 3 Auxiliary burner up to 1 kW 4 Semi rapid burner up t...

Страница 7: ...hting the flame Switching off a burner Turn the corresponding control knob clockwise to the 0 setting Power levels The progressive control knobs can be used to control the power needed from minimum to maximum power For dual double flame burners the inner and outer flames can be controlled separately The available power levels are as follows Warnings It is normal to hear a soft whistling noise whil...

Страница 8: ...s e g lemon juice vinegar etc on the hob Due to the high temperatures endured the wok burner and the stainless steel zones grease drip tray burner outline etc can change colour This is normal After each use clean these areas with a product that is suitable for stainless steel It is recommended that the cleaning product available from our Technical Assistance Service code 464524 is used regularly B...

Страница 9: ... The burners are wet Dry the burner caps carefully The burner caps are not correctly positioned Check that the burner caps are correctly posi tioned The appliance is not earthed is poorly connected or the earthing is faulty Contact the installation technician The burner flame is not uni form The burner components are not correctly posi tioned Correctly place the parts on the appropriate burner The...

Страница 10: ...10 Wiring diagram A Switch B Blue wire C Brown wire D Terminal E Ignition module ...

Страница 11: ...G 9000858158 9000858158 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...