Maintenance
No special maintenance is required other than occasionally cleaning the window with water or
any non-aggressive liquid.
Fuse replacement
1.
To replace a fuse, push and twist the fuse holder to open it.
2.
Replace the fuse with a fuse that has the same current rating. The fuse is a 5 mm x
20 mm slow blow breaking capacity cartridge-type fuse.
3.
Push and twist the fuse holder to close it.
Housing voltage
Fuse rating
24 VAC
4 A, 250 VAC
120 VAC
2 A, 250 VAC
230 VAC
2 A, 250 VAC
There is a spare fuse inside the housing.