Designation
Symbol
Unit
Definition
Thermal time constant
T
th
Duration of the temperature rise to 63% of the final temperature of the motor
housing at motor load with permissible S1 continuous torque. The thermal
time constant is determined by the cooling type used.
① : Chronological course of the motor housing temperature
Θ
max
: Highest temperature (motor housing)
T
th
: Thermal time constant
Maximum speed
n
max
min
-1
Maximum permissible speed of the motor. Centrifugal forces or bearing
stress can result in mechanical and DC bus voltage can result in electrical
limiting factors.
Mass
3)
m
kg
Motor mass
Ambient temperature during opera‐
tion
T
amb
Admissible ambient temperature during operation
Installation altitude
Maximale installation altitude
Insulation class according to DIN
EN 60034-1
---
-
Insulation class
Protection class acc. to IEC60529
---
-
IP type of protection
Sound pressure level
L
P
Value of sound emission
1) 2)
Manufacturing tolerance ±5%
3)
(...) Values for motors with holding brake
Tab. 5-1:
Definition of parameters
Bosch Rexroth AG
DOK-MOTOR*-MSM********-DA05-EN-P
20/61
Synchronous Servomotors MSM
Technical data
Содержание MSM019A
Страница 1: ...Synchronous Servomotors MSM Data Sheet R911329338 Edition 05 ...
Страница 8: ...Bosch Rexroth AG DOK MOTOR MSM DA05 EN P 6 61 Synchronous Servomotors MSM ...
Страница 46: ...Bosch Rexroth AG DOK MOTOR MSM DA05 EN P 44 61 Synchronous Servomotors MSM ...
Страница 56: ...Bosch Rexroth AG DOK MOTOR MSM DA05 EN P 54 61 Synchronous Servomotors MSM ...
Страница 63: ...Notes DOK MOTOR MSM DA05 EN P Bosch Rexroth AG 61 61 Synchronous Servomotors MSM ...