40
en | Appendices
MIC IP starlight 7000i
2017.09 | 0.12 | F.01U.xxx.xxx
Installation Manual
Bosch Security Systems
Status
Code
Description
Recommended action
(to be completed by a qualified Service
Technician)
7
Camera may be operating in an
environment where ambient
temperature is below the
specification of the camera.
1. Verify that the ambient temperature is not
below -40 °C (-40 °F).
2. Review the diagnostic log of the camera
(accessible from the
Service
menu) for errors
related to the operation of the internal
heaters.
Note
: Motorized zoom and focus functions of
the visible camera lens will be disabled until
the camera operates within the specified
temperature range.
8
Camera may be operating in an
environment where ambient
temperature is above specification
of the camera.
1. Verify that the ambient temperature is not
above +65 °C (+149 °F).
2. Review the diagnostic log of the camera
(accessible from the
Service
menu) for errors
related to the operation of the internal fan.
3. Add the optional sunshield accessory to
reduce internal heating caused by sun
loading.
9
Camera has been subjected to high
shock. Mechanical damage to the
camera may exist.
1. Verify the integrity of the mechanical parts
such as the arms and the pan body.
2. Verify the integrity/tightness of the
external fasteners. Tighten where necessary.
3. If obvious damage is present, stop using
the camera and contact the nearest Bosch
Security Systems Service Center.
4. If no damage is evident, power the camera
off and then on, and then evaluate
operational performance. If the camera does
not operate as expected, contact the nearest
Bosch Security Systems Service Center.