background image

EN

| 32

LTC 8900 | 

User Manual

Error Messages

Bosch Security Systems | March 17, 2009

Error 

Description 

Error 

Description 

Error 55 - 
SEQUENCE priority

The switcher sequence being requested or
cleared requires monitors that are in use by
a user of equal or higher priority. Contact
a user with higher priority, or have the
system administrator clear the monitors in
question.

Error 80 - 
Trunk not available 

An attempt was made to access a
remote camera connected to a
satellite system, but no unused
trunk lines are currently available.

Error 56 - 
SEQUENCE request

The user has tried to load a sequence that
is being edited in the 

PROGRAM

mode.

Once editing has been completed, the
sequence may be loaded.

Error 81 - 
Satellite Trunk Seized

The camera currently viewed has
changed because an operator with
a higher priority has selected a
different camera that seized the
trunk line from the satellite.

Error 58 - 
SEQUENCE request

The sequence being requested is a Relative
sequence, and the user is only permitted
access to Absolute sequences.

Error 89 - 
Internal stack error

A stack overflow has occurred
within the system. Report this to
the manufacturer.

Error 60 - 
PROGRAM request

The user has tried to program a sequence
that is currently running. The sequence
must first be stopped before any editing
can be performed.

Error 90 - 
Keyboard entry undefined

The keyboard entry is not defined.
Check the appropriate section of
this manual for the desired
operation, and try again.

Error 62 - 
PROGRAM request

The user has tried to program a new
sequence when the system is out of
sequence memory space. Delete unused
sequences and then program the new
sequence.

Error 92 - Keyboard entry out of
range

The data entered for a valid
command was not in the permitted
range. Check the appropriate
section of this manual for the
acceptable ranges for the
command in question and try
again.

Error 63 - 
PROGRAM request

Some other user is already programming a
sequence on this monitor.

Error 94 - Keyboard entry invalid 

An invalid character has been
received from the keyboard,
usually caused by a
communication error. Verify that
the keyboard-to-system cable is
securely connected. 

Error 70 - 
Monitor not allocated
to alarm monitor
group

This monitor cannot be used for alarm
operations; it has not been designated as
alarm-capable by the system programmer.

Error 95 - Keyboard entry
incomplete

The control sequence sent from the
keyboard was incomplete, usually
indicating a communication error.
Verify that the keyboard-to-system
cable is not producing an
intermittent connection.

Error 71 - 
Step monitor required

A group of alarm monitors may not have
an armed Review (display) monitor without
having armed Step (sequence) monitors.

Error 96 - * (STAR) undefined

The 

*

key has been pressed, but

there is no definition for this
button.

Error 78 - 
Must enter alarm
number

A specific alarm number must be entered
when arming or disarming an alarm. 

Warning Messages 

- Hi/Low Temperature Alert

The Allegiant CPU is equipped with a temperature sensor.  If the
ambient CPU temperature drops below -10 degrees C or goes above
+55 degrees C, an on-screen "Temperature Alert" message will appear
on the system monitors and the system keyboards will begin to beep.

Содержание LTC 8900 Series

Страница 1: ...LTC 8900 Series User Manual EN Allegiant Microprocessor based Video Switcher Control Systems CPU Firmware Version 10 0 ...

Страница 2: ...mpts 6 3 6 Camera Number 7 3 7 Camera Title 7 3 8 Video Loss Detection 7 4 USER INFORMATION 7 4 1 User Priority Access Table 8 5 KEYBOARD OPERATION 8 5 1 General 8 5 2 System Commands 8 5 3 Switcher Commands 9 5 4 Controlling Camera Movement 9 5 5 Alarm Commands 11 5 6 Sequence Control 12 5 7 Sequence Programming 13 6 KEYBOARD USER FUNCTIONS 14 6 1 General 14 7 MAINTENANCE 23 7 1 Cleaning the Keyb...

Страница 3: ... 4 digit camera number mode 15 Selectable time date format 16 Local keyboard test function 17 Table and Sequence printout feature 18 Selectable RS 232 communication parameters 19 Integral video loss detection 20 Satellite system configurations 21 Restrictions for user keyboard access to cameras 22 Restrictions for user keyboard access to receiver drivers 23 Restrictions for user access to keyboard...

Страница 4: ...en down into three areas as shown in the FIGURE 1 below 3 1 Time Date The time date display is generated by the system CPU microprocessor module It is crystal controlled and battery protected for one year minimum without power The display is updated once per second and all monitors update simultaneously The time date message is always on the right hand side of the video display with the time on th...

Страница 5: ... using symbols described 3 2 3 Location 4 Monitor Arm Status Indication In the MONITOR ARMED location the characters SM or DM will appear if the monitor is armed for alarm SM means that the monitor is a step or sequence monitor and will automatically step through multiple alarm videos DM indicates that the monitor is a display or review monitor which will collect alarm videos from one or more step...

Страница 6: ...ontrol Software on a PC 3 2 9 Locations 10 and 11 Sequence Number The sequence number currently active for the monitor is displayed here This is a number between 1 and 60 or 00 to indicate that no sequence is loaded 3 2 10 Location 12 Sequence Status Indication This location indicates the status of the sequence active in the monitor Possible character combinations are 1 R the current sequence is s...

Страница 7: ...DEO NOT PRESENT message is displayed on the respective monitor NOTE It may take up to five seconds for the unit to display the video loss message when a video source is disconnected 4 USER INFORMATION There are 64 levels of user priority in the Allegiant system Each of the 128 users in the Allegiant system has a default priority level assignment These user levels determine access to various system...

Страница 8: ...User specific priority levels can only be changed via the PC based LTC 8059 Master Control Software MCS program Refer to the MCS manual for details If the logon feature is enabled and an operator is not logged in LED keyboards show flashing dashes in their display IntuiKey keyboards prompt for a user number when entering the main Allegiant softscreen menu Priority Levels System Function 1 2 to 7 8...

Страница 9: ...oves the camera in a diagonal direction Rotating the ZOOM control knob causes the lens to either zoom in or out The direction of its response depends on the camera lens model and certain system configuration settings determined at installation Up to four pan tilt zoom commands may be sent to a remote camera site at a time Example Zoom In Focus Far Pan Left and Tilt Down The three zoom lens functio...

Страница 10: ...if this feature is supported 5 4 6 Recalling a Camera Pre position Scene Select the camera to be activated Press Shot enter a previously stored camera position number via the numeric keypad then press ENTER The camera automatically returns to the previously stored position If a second pre position is called prior to the completion of the first the camera will move directly to the second shot If th...

Страница 11: ... disarm an individual alarm when using LTC 8555 Series keyboards press Alarm enter the alarm number to be armed via the numeric keypad and press ON to arm the alarm or OFF to disarm it Using default settings the camera activated by an alarm is normally the same as the alarm number although this relationship can be changed via the Allegiant PC based MCS package When the alarm number does not match ...

Страница 12: ...s display now shows S to the right of the sequence number If the sequence is already stopped pressing Hold Sequence Hold has no effect If no sequence is currently loaded pressing Hold Sequence Hold results in an error condition If the monitor is in alarm Hold Sequence Hold stops the alarm switcher rather than a loaded sequence 5 6 4 Controlling Sequence Direction The direction of a sequence can be...

Страница 13: ...digits must be entered If the camera number is correct no action is necessary If not enter the desired camera number via the keypad and press ENTER Using the joystick move RIGHT one step The prompts will shift over to the monitor number shown in the example as M001 The monitor that was being controlled by the keyboard before entering the programming mode defaults to this position If correct no act...

Страница 14: ...SLV 23 3 2 In general follow the instructions used for the simple camera sequence described above but instead of entering a number of seconds for steps that must switch instantly enter 61 and press ENTER This causes the switcher to automatically change to the salvo abbreviation SLV Dwell time in seconds is entered only when you reach the step containing the last monitor to be switched within the s...

Страница 15: ...ormat fixed variable Y N N 23 n a n a Display CPU software version number Y Y Y 24 Up Down Left Right Set positions on all monitor displays Y Y N 25 Brightness Msg vs Stat Set brightness on all monitor displays Y Y N 26 Time Date Overlay Set display option on all monitors Y Y N 27 Keyboard Login Select Select keyboard login Y N N Y 28 Console Login Select Select console login Y N N Y 29 Default Pa...

Страница 16: ... 1 5 User Function 4 Adjust Position of Monitor Overlay User Function 4 allows the characters on the video monitor display to be positioned from the keyboard Only the display on the monitor that the keyboard is currently connected to is effected If using the LTC 8555 Series keyboard use the joystick to position the display as required Press ENTER to store the position and then press USER to exit 6...

Страница 17: ...ng If desired this message can be used to identify the scene being viewed Refer to SECTION 8 LTC 8900 CHARACTER SET for the available characters After entering the mode users with priority level 1 can use the joystick to move right left to select the character to be changed The selected character will be identified by a box with a question mark inside it The first line of the video monitor screen ...

Страница 18: ...nd to the left disables it The current status of an enabled time event is displayed by this user function 6 1 18 User Function 17 Set Monitor ID User Function 17 can be used by users with the priority level 1 to enter a 12 character monitor identification message for display in the top line of the monitor overlay display on any system monitor s This monitor title will be visible on the display reg...

Страница 19: ...een 6 1 25 User Function 24 Set Positions on All Monitor Displays This function is similar to User Function 4 except it changes the monitor display positions of all monitors in the system After entering User Function 24 use the joystick to position the display as required on the monitor controlled by the keyboard Press ENTER to store and change all system monitor displays to this position If using...

Страница 20: ...9 Reset RS 232 Parameters to Default This function returns the system s external RS 232 ports to a known default state After entering the mode enter a valid password The system will reset after placing the RS 232 protocols back to the default state 6 1 31 User Function 30 Set Controller RS 232 Parameters Priority level 1 users can select the RS 232 baud rate and handshake options for the system s ...

Страница 21: ...elect the console port function NORMAL or EXPANDED Press ENTER to activate your selection You must reset the system for this setting to take effect 6 1 40 User Function 39 Select DIU Interface Port Priority 1 users can use this function to select the switcher s interface port to be connected to an external Allegiant BilinxTM Data Interface accessory unit Move the joystick up down until the desired...

Страница 22: ...riority to determine if access to a desired satellite camera is provided or not For instance if no Trunk Lines are available and an operator requesting a satellite camera has higher priority than at least 1 of the existing operators the requested camera will be switched If the operator does not have sufficient priority they will receive an error message i e error 81 via the satellite communication...

Страница 23: ...tion to the 4 digit camera number The 2 digit site number feature is especially useful when groups of cameras are located in separate buildings floors or other common areas By default all 6 digit camera numbers are assigned to site 00 and the remaining digits correspond to the standard 4 digit camera numbers Use the PC based LTC 8059 Master Control Software to enter unique 6 digit camera numbers f...

Страница 24: ...EN 24 LTC 8900 User Manual LTC 8900 Character Set 8 LTC 8900 CHARACTER SET Bosch Security Systems March 17 2009 ...

Страница 25: ...EN 25 LTC 8900 User Manual Character Set Bosch Security Systems March 17 2009 ...

Страница 26: ...EN 26 LTC 8900 User Manual Character Set Bosch Security Systems March 17 2009 ...

Страница 27: ...LTC 8900 User Manual LTC 8900 Character Set EN 27 Bosch Security Systems March 17 2009 ...

Страница 28: ...LTC 8900 User Manual LTC 8900 Character Set EN 28 Bosch Security Systems March 17 2009 ...

Страница 29: ...LTC 8900 User Manual LTC 8900 Character Set EN 29 Bosch Security Systems March 17 2009 ...

Страница 30: ...LTC 8900 User Manual LTC 8900 Character Set EN 30 Bosch Security Systems March 17 2009 ...

Страница 31: ...led for acknowledge This keyboard may not acknowledge alarm video on this monitor it has been disabled by the system programmer Error 06 Monitor access restricted Monitor is locked out by Monitor Lock Out Table Error 25 Alarm switcher running Alarm video may only be acknowledged if the alarm switcher is not running press HOLD to stop the switcher Error 10 Access denied A function was requested tha...

Страница 32: ...as tried to program a new sequence when the system is out of sequence memory space Delete unused sequences and then program the new sequence Error 92 Keyboard entry out of range The data entered for a valid command was not in the permitted range Check the appropriate section of this manual for the acceptable ranges for the command in question and try again Error 63 PROGRAM request Some other user ...

Страница 33: ... integrated cameras giving a roll free video display when switching from one camera to the next in a sequential switcher system Phased cameras are the result of line locked cameras powered from the same AC power externally synchronized or vertically phase adjusted on cameras equipped with this option PRE POSITION The ability to store the position of a pan tilt zoom lens so that the desired scene c...

Страница 34: ...EN 34 LTC 8900 User Manual Bosch Security Systems March 17 2009 ...

Страница 35: ...EN 35 LTC 8900 User Manual Bosch Security Systems March 17 2009 ...

Страница 36: ...w boschsecurity us E Eu ur ro op pe e M Mi id dd dl le e E Ea as st t A Af fr ri ic ca a B Bo os sc ch h S Se ec cu ur ri it ty y S Sy ys st te em ms s B B V V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com A As si ia a P Pa ac ci if fi ic c B Bo os sc ch h S Se ec cu ur ri it ty y S Sy ys st te em ms s P...

Отзывы: