EN
| 32
LTC 8900 |
User Manual
|
Error Messages
Bosch Security Systems | March 17, 2009
Error
Description
Error
Description
Error 55 -
SEQUENCE priority
The switcher sequence being requested or
cleared requires monitors that are in use by
a user of equal or higher priority. Contact
a user with higher priority, or have the
system administrator clear the monitors in
question.
Error 80 -
Trunk not available
An attempt was made to access a
remote camera connected to a
satellite system, but no unused
trunk lines are currently available.
Error 56 -
SEQUENCE request
The user has tried to load a sequence that
is being edited in the
PROGRAM
mode.
Once editing has been completed, the
sequence may be loaded.
Error 81 -
Satellite Trunk Seized
The camera currently viewed has
changed because an operator with
a higher priority has selected a
different camera that seized the
trunk line from the satellite.
Error 58 -
SEQUENCE request
The sequence being requested is a Relative
sequence, and the user is only permitted
access to Absolute sequences.
Error 89 -
Internal stack error
A stack overflow has occurred
within the system. Report this to
the manufacturer.
Error 60 -
PROGRAM request
The user has tried to program a sequence
that is currently running. The sequence
must first be stopped before any editing
can be performed.
Error 90 -
Keyboard entry undefined
The keyboard entry is not defined.
Check the appropriate section of
this manual for the desired
operation, and try again.
Error 62 -
PROGRAM request
The user has tried to program a new
sequence when the system is out of
sequence memory space. Delete unused
sequences and then program the new
sequence.
Error 92 - Keyboard entry out of
range
The data entered for a valid
command was not in the permitted
range. Check the appropriate
section of this manual for the
acceptable ranges for the
command in question and try
again.
Error 63 -
PROGRAM request
Some other user is already programming a
sequence on this monitor.
Error 94 - Keyboard entry invalid
An invalid character has been
received from the keyboard,
usually caused by a
communication error. Verify that
the keyboard-to-system cable is
securely connected.
Error 70 -
Monitor not allocated
to alarm monitor
group
This monitor cannot be used for alarm
operations; it has not been designated as
alarm-capable by the system programmer.
Error 95 - Keyboard entry
incomplete
The control sequence sent from the
keyboard was incomplete, usually
indicating a communication error.
Verify that the keyboard-to-system
cable is not producing an
intermittent connection.
Error 71 -
Step monitor required
A group of alarm monitors may not have
an armed Review (display) monitor without
having armed Step (sequence) monitors.
Error 96 - * (STAR) undefined
The
*
key has been pressed, but
there is no definition for this
button.
Error 78 -
Must enter alarm
number
A specific alarm number must be entered
when arming or disarming an alarm.
Warning Messages
- Hi/Low Temperature Alert
The Allegiant CPU is equipped with a temperature sensor. If the
ambient CPU temperature drops below -10 degrees C or goes above
+55 degrees C, an on-screen "Temperature Alert" message will appear
on the system monitors and the system keyboards will begin to beep.
Содержание LTC 8900 Series
Страница 25: ...EN 25 LTC 8900 User Manual Character Set Bosch Security Systems March 17 2009 ...
Страница 26: ...EN 26 LTC 8900 User Manual Character Set Bosch Security Systems March 17 2009 ...
Страница 27: ...LTC 8900 User Manual LTC 8900 Character Set EN 27 Bosch Security Systems March 17 2009 ...
Страница 28: ...LTC 8900 User Manual LTC 8900 Character Set EN 28 Bosch Security Systems March 17 2009 ...
Страница 29: ...LTC 8900 User Manual LTC 8900 Character Set EN 29 Bosch Security Systems March 17 2009 ...
Страница 30: ...LTC 8900 User Manual LTC 8900 Character Set EN 30 Bosch Security Systems March 17 2009 ...
Страница 34: ...EN 34 LTC 8900 User Manual Bosch Security Systems March 17 2009 ...
Страница 35: ...EN 35 LTC 8900 User Manual Bosch Security Systems March 17 2009 ...