![Bosch LM024 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/bosch/lm024/lm024_operating-instructions-manual_44205011.webp)
Comfort Alert Module
|
11
LM CS Series Heat
8 733 920 847 (2014/01)
Revised 01-14
Figure 10: Refrigerant Charge, Line Sizing and Capacity Multiplier Chart
SYSTEM
MODEL
Factory
R410A
Charge
(Oz)*
Refrigerant Line O.D. Size (Based on Equivalent Line Length)
Suct. Line
Riser Max.
25 FT.
35 FT.
45 FT.
50 FT.
75 FT
LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC.
LM024
80
3/8
3/4
3/8
3/4
3/8
3/4
3/8 3/4 3/8
7/8
3/4
LM036
86
3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8
7/8
3/4
LM048
93
3/8 7/8 3/8 7/8 3/8 7/8 3/8 7/8 3/8
7/8
7/8
LM060
115
3/8 1-1/8 3/8
1-1/8
3/8
1-1/8
3/8
1-1/8
3/8
1-1/8
7/8
LM070
127
3/8 1-1/8 3/8
1-1/8
3/8
1-1/8
3/8
1-1/8
3/8
1-1/8
7/8
CAPACITY MULTIPLIER
1.00
.995
0.990
0.990
0.980
Example 1:
Model LM036 with 45ft of equivalent length of 3/8” O.D Liquid
Line. Total system charge= Factory (45ft - 25 ft) x .60
oz/ft Total System Charge = 93 oz + (20ft x .60 oz/ft) = 105 oz.
Additional 12 oz of R410A refrigerant required.
Example 2:
Model LM060 with 10ft of equivalent length of 3/8” O.D
Liquid Line. Total system charge= Factory (25ft -
10ft) x .60 oz/ft Total System Charge = 150 oz + (15ft x .60
oz/ft) = 141 oz. Additional 12 oz of R410A refrigerant
required.
Figure 11: Liquid Line Charge Per Linear Foot
Liquid Line Size, O.D.
1/4
5/16
3/8
1/2
5/8
R410A oz per foot
.25
.44
.60
1.15
1.95