22
en | Installation
LECTUS select
2021-02 | 01 | F.01U.389.837
Installation manual
Bosch Security Systems B.V.
2.5.3
Unmounting the reader module
1.
Unlock the locking bar. To do this, use the screwdriver with the blade max. 4 mm wide
into the unlocking openings and press until the lock releases.
2.
Pull out the unlocked locking bar and remove it from the reader module.
3.
Push the reader module upwards to release it and lift it off forwards.
1
2
i
Notice!
Any changes that are done to the DIP-switches while the power is on are not considered.
2.5.4
Resetting OSDP-key
Upon delivery from the factory, each reader is set to the ‘OSDP installation mode’ to active.
When operating a reader with an AMC using OSDP secure channel, a dedicated generated
encryption key secures operation and prevents the use of the reader in a different site.
Should it be necessary to change the connection to another access modular controller, then
the OSDP-key must be reset.
It is necessary to reset the OSDP-key:
–
if readers and/or access modular controllers need to be changed.
–
if the reader must be disposed.
1.
Disconnect the reader from the socket.
2.
Set all DIP-switches to
OFF
.
3.
Connect the reader to the cable for power-up.
–
The reader emits a “beep” sound.
–
A green LED starts flashing.
4.
Disconnect the reader again.
–
The reader is now back in ‘OSDP installation mode’.
–
The reader can now be used as a new reader.