5.13.4
Low Battery Indication
The detector indicates a low battery condition in two ways:
–
If the EVENT and ALARM LEDs are enabled, both LEDs
flash simultaneously every second.
–
A battery status indication is transmitted from the glass
break detector to the wLSN Diversity Hub, and then
transmitted from the hub to the control panel.
The flashing LEDs and a low battery indication at the control
panel are independent of each other and do not necessarily
occur at the same time. Receiving either condition indicates a
low battery.
5.13.5
Entering RFSS Mode
To enter RFSS Mode if the wall tamper tab is removed:
1.
Take the detector to its planned mounting location.
2.
Remove and reinsert the batteries.
3.
Press and hold the wall tamper switch. Refer to
4.
Quickly press and release the cover tamper switch four
times within 10 sec of reinserting the batteries. Refer to
. The detector enters RFSS Mode.
Figure 5.22
Wall and Cover Tamper Switches
Callout
Description
1
Wall tamper switch (back of detector)
2
Cover tamper switch (inside of detector)
2
1
12
O N
CTS-2
TEST
SW4
ID:000000000