24
en | wLSN Devices
wLSN
F01U138553 | 01 | 2010.05
System Reference Guide
Bosch Security Systems, Inc.
5.3.2
Walk Test
Perform a walk test to determine the boundaries of the
coverage area.
You can start a walk test from from the control panel or from
the detector.
–
Control Panel:
Enter the appropriate command sequence
at the control panel to start the Walk Test mode (refer to
the control panel’s documentation).
–
Detector:
Slide open and then close the detector cover to
start a 90-sec walk test.
Detected motion within the detector’s coverage area activates
the red LED, transmits a signal to the control panel, and
restarts a 90-sec timer. If no motion occurs within 90 sec, the
red LED flashes for the last 10 sec to indicate that the Walk
Test mode is ending. Detected motion restarts the 90-sec timer.
1.
Start at the pattern’s expected boundary and walk across
the pattern, moving closer to the detector at each pass
while observing the LED. Refer to
.
Refer to
for PIR LED indications, and to
for dual motion LED indications.
Figure 5.5
Walk Test
Table 5.6
PIR Walk Test LED Indications
NOTICE!
To maximize battery life, the LED elements do not activate
unless the detector is in the Walk Test mode.
LED Color
Function
Red – fast flash
Power-up (Walk Test disabled)
Red – lights for 4 sec
Alarm, motion detected