Connecting to the IntuiKey
1.
Refer to
Figure 3.8
for details on the input/output connections supplied by the IntuiKey
Keyboard. Four connectors are located on the IntuiKey rear panel: (2) RJ-11 connectors,
(1) female 9-pin sub-D connector, and a DC power jack. The RJ-11 connectors are labeled
as Allegiant and MUX/DVR and the 9-pin sub-D is labeled
RS-232 Serial Port
.
Figure 3.3
Back Panel Connections of IntuiKey
2.
If desired, the data/power cables can be looped through either of the two tabs found at
the bottom of the rear panel to increase strain relief capabilities.
3.
Review the configuration options shown in
Figure 3.9
. Make the necessary keyboard data
and power connections that are best suited to your system requirements based on these
diagrams. When connecting to a Divar Series DVR or to a System4 Multiplexer, attach the
supplied 390
?
terminator to the
Out
connector on the last device.
MUX / DVR
ALLEGIANT
12 VDC
RS-232 SERIAL PORT
MUX/DVR
DC Power
Allegiant
RS-232
Serial Port
Cable Strain Reliefs
!
CAUTION!
To ensure proper system functioning and to prevent damage to the unit, it is
critical that only Allegiant devices be connected to the Allegiant connector, and that
Multiplexer/DVR devices be connected to the MUX/DVR connector.
i
NOTICE!
In systems having multiple Divar Series DVRs or multiple System4 Multiplexers, use
the front panel controls on the video devices to assign appropriate address numbers and
starting camera numbers. The IntuiKey will not properly recognize the video devices if there
are conflicting addresses in the system.