Fig. 9-5: USB ports
The maximum current carrying capacity of the USB3.0 interface
XF30 is 900 mA. The maximum current carrying capacity of the
USB2.0 interfaces XF31, XF32, XF33 is 500 mA.
9.4 Ethernet interfaces XF5, XF6
The embedded automation computer can be connected to an Ethernet network
via the Ethernet interfaces XF5 and XF6.
9.5 Video interface
A monitor with HDMI port can be connected to the HDMI video port (XF13).
9.6 2 x GBit LAN
2 x GBit LAN are available as ordering option "B" under interface extensions.
10 Mounting, assembly and electrical installation
Mechanic damage due to incorrect mounting
torque.
NOTICE
Tighten the screws and nuts with the corresponding torque according to the fol-
lowing table.
Thread
Mounting torque
M2.5
0.4 Nm
M3
0.7 Nm
M4
1.4 Nm
M5
1.0 Nm
Tab. 10-1: Mounting torque