ICP-CC404
|
Installation Guide | 1.0
Introduction
8
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
When programming the telephone numbers for
Receiver 1 and Receiver 2, you must program a 0
as a 10. Programming a 0 in the telephone
number indicates the end of the dialing sequence.
Unless otherwise stated, program a 0 as a 0 in all
locations other than the telephone numbers for
Receiver 1 and Receiver 2, and the Call Back
Telephone Number.
6.
If required, set the Test Report time. Program
any other required changes. Otherwise, factory
default settings are used. Refer to
Section 15.21
Test Reporting Time
on page 63 for more
information.
7.
Enter command [9 6 0] and press [AWAY] to exit
from the Installer’s Programming Mode.
Two beeps sound and the STAY and AWAY
indicators turn off. The system returns to the
disarmed state and is ready for use. Refer to
Section 2.4 Installer’s Programming Commands
on
page 10 for more information.
8.
Use the Master Code to set the date and time.
Refer to
Section 1.2.1 Setting the Date and Time
for
more information.
1.2.1
Setting the Date and Time
1.
Enter your Master Code and press [6][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
2.
Enter the day, month, year, hour, and minute in
DD, MM, YY, HH, MM format (where DD is the
day of the month, MM is the month of the year,
YY is the year, HH is the hour of the day, and
MM minute of the day) and press [AWAY].
Use 24:00 hour format when programming the
hour of the day.
Two beeps sound and the STAY and AWAY
indicators turn off. If a long beep sounds, there
was an error when you entered the date and time.
Example
To set the date and time for the 1st January 2006 at
10:30 PM, enter:
[2 5 8 0 6][AWAY][0 1 0 1 0 6 2 2 3 0][AWAY]
1.2.2 Zone
Defaults
The default zone settings for the control panel are
listed in
Table 1
. You can program Zones 1 to 4 to
any of the zone types. Refer to
Table 2
for the zone
types you can select.
Table 1:
Zone Defaults
Zone Zone
Type
Zone
Zone
Type
1
Delay-1
5
24-Hour Burglary
2 Handover
6
24-Hour
Burglary
3
Handover
7
24-Hour Fire
4 Instant
8
24-Hour
Tamper
1.2.3 Zone
Types
There are thirteen zone types to choose from when
programming zones for the ICP-CC404 Control
Panel. Refer to
Section 14.3 Zone Programming
on
page 54 for more information.
Table 2:
Zone Types
Type Description
Type Description
0
Instant
8
24-Hour Holdup
1 Handover
9 24-Hour
Tamper
2
Delay-1
10
Reserved
3 Delay-2
11
Keyswitch
4
Reserved
12
24-Hour Burglary
5 Reserved
13
24-Hour
Fire
6
24-Hour Medical
14
Chime only
7 24-Hour
Panic
15
Zone
not
used