![Bosch ICP-CC404 Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/bosch/icp-cc404/icp-cc404_installation-manual_39351044.webp)
ICP-CC404
|
Installation Guide | 10.0 Dialer Reporting Formats
44 Bosch
Security
Systems,
Inc. | 12/08 | F01U089401-02
Table 36:
4+2 Express Transmission Code
Descriptions
Code
Description
SSSS
Subscriber ID Number
A Alarm
C
H
Channel Number
0 Zero
T
Trouble
B Bypass
E
AC Fail Code 1
st
digit
AC
AC Fail Code 2
nd
digit
L
Low Battery Code 1
st
digit
L
B
Low Battery Code 2
nd
digit
O
Open
C Close
U
User Number
R
Alarm Restore Code
TR
Trouble Restore Code
B
R
Bypass Restore Code
E
R
AC Fail Restore Code 1
st
digit
AC
R
AC Fail Restore Code 2
nd
digit
L
R
Low Battery Restore Code 1
st
digit
L
BR
Low Battery Restore Code 2
nd
digit
D
Duress Code 1
st
digit
D
0
Duress
Code
2
nd
digit
P
Panic Code 1
st
digit
P
CH
Panic
Code
2
nd
digit
T
E
Test Code
10.1.4 Basic
Pager
Reporting Format
Although Basic Pager Format requires some
interpretation of the numbers that appear on the
display, it can differentiate between 1000 different
control panels if a number of control panels report to
the one pager.
To set up Receiver 1 for basic pager reporting:
1.
Program the Basic Pager’s access telephone
number in Locations 000 to 015 (refer to
Section
11.1 Primary Telephone Number for Receiver 1 and
Receiver 2
on page 46).
2.
Program the Subscriber ID Number in Locations
034 to 039 (refer to
Section 11.5 Subscriber ID
Number for Receiver 1 and Receiver 2
on page 47).
3.
Select Pager Handshake (Option 5) in
Location 032 (refer to
Section 11.3 Handshake Tone
for Receiver 1 and Receiver 2
on page 47).
4.
Program Basic Pager Format (Option 5) in
Location 033 (refer to
Section 11.4 Transmission
Format for Receiver 1 and Receiver 2
on page 47).
To set up Receiver 2 for basic pager reporting:
1.
Program the Basic Pager’s access telephone
number in Locations 040 to 055 (refer to
Section
11.1 Primary Telephone Number for Receiver 1 and
Receiver 2
on page 46).
2.
Program the Subscriber ID Number in Locations
074 to 079 (refer to
Section 11.5 Subscriber ID
Number for Receiver 1 and Receiver 2
on page 47).
3.
Select Pager Handshake (Option 5) in Location
072 (refer to
Section 11.3 Handshake Tone for
Receiver 1 and Receiver 2
on page 47).
4.
Program Basic Pager Format (Option 5) in
Location 073 (refer to
Section 11.4 Transmission
Format for Receiver 1 and Receiver 2
on page 47).
The example in
Figure 6
shows:
•
Transmission from Subscriber ID Number 5678
•
Zone 2 in alarm
•
Zone 3 manually isolated
•
The system is armed
•
The Panic Zone is normal
•
The AC is connected
•
There is no fault condition.