15
Electrical Installation
9
WARNING
The electrical connection of the appliance must be
carried out by a qualified electrician.
9
CAUTION
Before installing, turn off at the service panel. Lock
service panel to prevent power from being turned
on accidentally.
9
WARNING
Local codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the hood to the white neutral
electrical supply wire.
Three-wire 120 V Connection
Remove the cover from the field wiring compartment with
a phillips screwdriver. Feed the power supply cable
through the electrical knockout.
Connect the power supply cable to the rangehood
cable:
▯
Connect white wire from hood to white wire from
power supply in junction box.
▯
Connect black wire from hood to black wire from
power supply in junction box.
▯
Connect green or bare neutral wire from power supply
to ground wire nut in junction box.
9
WARNING
RISK OF ELECTRIC SHOCK
Do not under any circumstances damage or remove
the green/yellow wire. Non-adherence can cause
deadly injuries or electric shock.
The conduit cable, where connected at the hood, flexes.
To maintain serviceability, the flex conduit must not be
shortened and should be routed to permit temporary
removal of the hood.
Using the 4 holes provided, screw the field wiring
compartment to the wall or cabinet as dictated by your
power supply cable location (screws not provided).
Replace the cover.
Removing the appliance
1.
Disconnect the appliance from the power supply.
2.
Pull out the filter drawer.
3.
Remove the two rear grease filters.
4.
Remove the fastening screws.
5.
Remove the appliance from the fitted unit.
SRZHUVXSSO\
EODFNZLUHV
\HOORZJUHHQZLUH
ZKLWHZLUHV
FDEOHIURPKRRG
MXQFWLRQER[
JUHHQRUEDUHZLUH
JURXQG
Содержание HUI50351UC
Страница 1: ...Installation Manual Hood HUI50351UC HUI56551UC ...