Electrical connection

Only a licensed expert may connect the appliance. The 

appliance must be installed according to the most recent IEE 

regulations (Institute of Electrical Engineers). The appliance 

may be damaged if incorrectly connected.
Make sure the voltage of the power supply corresponds to the 

specified value on the rating plate. The rating plate can be 

found on the inside of the storage compartment flap.
Ensure that the power supply is properly earthed and that the 

fuse and the wiring and piping system in the building can 

withstand the load from the appliance.
It is recommended that you configure the circuit for the 

appliance to 16 A.
When you route the cable, make sure that:

the cable is not trapped or squashed.

the cable, for example, does not come into contact with 

sharp edges or cutting edges.

the cable does not come into contact with parts that can 

reach temperatures of more than 50°C above room 

temperature.

Connecting the appliance to the power supply

The appliance corresponds to protection class 1 and may only 

be operated with a protective earth connection.
The appliance must be disconnected from the power supply for 

all installation work.
The appliance must only be connected to the power supply with 

the power cable provided.
Contact protection must be ensured by the installation.
Only a licensed expert may connect the appliance. He is 

subject to the regulations of the local electricity provider.

Power cable without a plug with earthing contact

An all-pole isolating switch with at least a 3 mm contact gap 

must be fitted in the installation. Identify the phase and neutral 

conductors in the socket. The appliance may be damaged if 

incorrectly connected.
Connection to nominal voltage 220-240V. Connect the wires of 

the mains power cable according to the colour coding: green/

yellow = PE conductor 

<

, blue = neutral conductor, brown = 

phase (external conductor).

GB, IE, NZ, IL, DK and AU

Fixed connection only.

Power cable with a plug with earthing contact

The appliance can also be connected using the enclosed plug 

with earthing contact to a properly installed earthed socket. The 

socket must be accessible after installation. If this is not the 

case, an all-pole isolating switch with a contact gap of at least 

3 mm must be included in the installation.

Gas connection

The supply connection point shall be accessible with the 

appliance installed.
Using the R½'' (for appliance side) connection adapter 

provided, connect the appliance with the associated gasket to 

a fixed connection pipe. For natural gas the regulator must be 

connected.

If using a flexible connection

 

This appliance is approved for connection by a CLASS B hose. 

Connection is in compliance with AS/NZS 5601.1

There are two ways to carry out the connection to the main 

gas line:

A: The appliance can be connected with rigid pipe.

B: Flexible Hose: If installing with a hose assembly, install 

with a hose assembly that complies with AS/NZS 1869 (AGA 

Approved), 10 mm ID, class Bor D, no more than 1.2 m long 

and in accordance with AS/NZS 5601.1. Ensure that the 

hose does not contact the hot surfaces of the oven, 

dishwasher or any other appliance that may be installed 

underneath or next to the applance. The hose should not be 

subjected to abrasion, kinking or permanent deformation and 

should be inspected along its entire length with the applance 

in the installed position. Unions compatible with the hose 

fittings must be used and all connections tested for gas 

leaks.

Before leaving - check all connections for gas leaks with soap 

and water. DO NOT use a naked flame for detecting leaks. 

Ignite all burners both individually and concurrently to ensure 

correct operation of gas valves, burners and ignition. Turn gas 

taps to low position and observe stability of the flame for each 

burner individually and all together.
When satisfied with the appliance, please instruct the user on 

the correct method of operation. In case the appliance fails to 

operate correctly after all checks have been carried out, refer to 

the authorised service provider in your area.

Converting the gas type

If the appliance is not already set up for the existing type of 

gas, the appliance must be converted. The conversion to a 

different type of gas must be carried out by an authorised 

expert in accordance with the applicable regulations. The rating 

plate indicates the type of gas and the gas pressure which 

have been pre-set in the factory.

The rating plate is located on the inside of the storage 

compartment flap.
In order to convert to a different type of gas, the nozzles must 

be replaced and the low flame and primary air may have to be 

adjusted.

Содержание HSB738156A

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: