Electrical connection
Only a licensed expert may connect the appliance. The
appliance must be installed according to the most recent IEE
regulations (Institute of Electrical Engineers). The appliance
may be damaged if incorrectly connected.
Make sure the voltage of the power supply corresponds to the
specified value on the rating plate. The rating plate can be
found on the inside of the storage compartment flap.
Ensure that the power supply is properly earthed and that the
fuse and the wiring and piping system in the building can
withstand the load from the appliance.
It is recommended that you configure the circuit for the
appliance to 16 A.
When you route the cable, make sure that:
■
the cable is not trapped or squashed.
■
the cable, for example, does not come into contact with
sharp edges or cutting edges.
■
the cable does not come into contact with parts that can
reach temperatures of more than 50°C above room
temperature.
Connecting the appliance to the power supply
The appliance corresponds to protection class 1 and may only
be operated with a protective earth connection.
The appliance must be disconnected from the power supply for
all installation work.
The appliance must only be connected to the power supply with
the power cable provided.
Contact protection must be ensured by the installation.
Only a licensed expert may connect the appliance. He is
subject to the regulations of the local electricity provider.
Power cable without a plug with earthing contact
An all-pole isolating switch with at least a 3 mm contact gap
must be fitted in the installation. Identify the phase and neutral
conductors in the socket. The appliance may be damaged if
incorrectly connected.
Connection to nominal voltage 220-240V. Connect the wires of
the mains power cable according to the colour coding: green/
yellow = PE conductor
<
, blue = neutral conductor, brown =
phase (external conductor).
GB, IE, NZ, IL, DK and AU
Fixed connection only.
Power cable with a plug with earthing contact
The appliance can also be connected using the enclosed plug
with earthing contact to a properly installed earthed socket. The
socket must be accessible after installation. If this is not the
case, an all-pole isolating switch with a contact gap of at least
3 mm must be included in the installation.
Gas connection
The supply connection point shall be accessible with the
appliance installed.
Using the R½'' (for appliance side) connection adapter
provided, connect the appliance with the associated gasket to
a fixed connection pipe. For natural gas the regulator must be
connected.
If using a flexible connection
This appliance is approved for connection by a CLASS B hose.
Connection is in compliance with AS/NZS 5601.1
There are two ways to carry out the connection to the main
gas line:
■
A: The appliance can be connected with rigid pipe.
■
B: Flexible Hose: If installing with a hose assembly, install
with a hose assembly that complies with AS/NZS 1869 (AGA
Approved), 10 mm ID, class Bor D, no more than 1.2 m long
and in accordance with AS/NZS 5601.1. Ensure that the
hose does not contact the hot surfaces of the oven,
dishwasher or any other appliance that may be installed
underneath or next to the applance. The hose should not be
subjected to abrasion, kinking or permanent deformation and
should be inspected along its entire length with the applance
in the installed position. Unions compatible with the hose
fittings must be used and all connections tested for gas
leaks.
Before leaving - check all connections for gas leaks with soap
and water. DO NOT use a naked flame for detecting leaks.
Ignite all burners both individually and concurrently to ensure
correct operation of gas valves, burners and ignition. Turn gas
taps to low position and observe stability of the flame for each
burner individually and all together.
When satisfied with the appliance, please instruct the user on
the correct method of operation. In case the appliance fails to
operate correctly after all checks have been carried out, refer to
the authorised service provider in your area.
Converting the gas type
If the appliance is not already set up for the existing type of
gas, the appliance must be converted. The conversion to a
different type of gas must be carried out by an authorised
expert in accordance with the applicable regulations. The rating
plate indicates the type of gas and the gas pressure which
have been pre-set in the factory.
The rating plate is located on the inside of the storage
compartment flap.
In order to convert to a different type of gas, the nozzles must
be replaced and the low flame and primary air may have to be
adjusted.
Содержание HSB738156A
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......