15
INSTALLATION INSTRUCTIONS
Safety precautions
Read and store these instructions carefully. Safe use can only
be guaranteed if the appliance has been installed by a
professional and in accordance with these assembly
instructions.
The appliance must be connected to the mains only by a
licensed and trained technician.
If you wish to convert to a different type of gas, call the after-
sales service.
The fitter or the installer is liable for damage or faults resulting
from incorrect assembly or installation.
When installing the appliance you must observe the building
regulations that are currently applicable and the regulations set
by the local electricity and gas suppliers (e.g. Germany: DVGW-
TRGI/TRGF; Austria: ÖVGW-TR).
Switch off the power and gas supply before carrying out any
work.
The information on the rating plate regarding voltage, gas type
and gas pressure must comply with the local connection
conditions.
Electrical appliances must always be earthed.
If an extractor hood is to be fitted, it must be fitted according to
the associated assembly instructions. Ensure that the hood is
fitted at least 750 mm clear of the hob.
This appliance must not be installed on boats or in vehicles.
Before installing
These instructions are intended for several models. Details may
vary, depending on the appliance model.
Read the following information about the appliance and the
guidelines for ventilation.
In this section, you will find information on
■
Unpacking
■
the appliance classes
■
the appliance dimensions
■
the distance from any adjacent furniture
■
the rating plate
Unpacking
Check the appliance for damage after unpacking it. Do not
connect the appliance if it has been damaged in transport.
Dispose of packaging in an environmentally-friendly manner.
Appliance class
This appliance corresponds to the following appliance classes:
Appliance dimensions
Take note of the specified dimensions.
Adjacent units
Adjacent units must be made of non-combustible material.
Adjacent unit fronts must be heat-resistant up to at least 90 °C.
If the appliance is installed close to other kitchen units, you
must comply with the minimum distances specified in the
diagram.
Appliance class
Description
Class 1
Non flush-fitted cooker
Class 2 - subclass 1
Cooker immediately adjacent to two
units, consisting of a single unit, can
also be installed so that the side
walls are accessible.
PP
PP
PP
PP
PP
PP
PP
Содержание HSB738156A
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......