5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 0.2 ~ 0.4 ohm
Approx.: 60 ~ 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
TERMINAL
FILAMENT
WINDING
TERMINAL
COMPONENT TEST PROCEDURE
Содержание HMB402
Страница 26: ...1005 1381 1000 1004 1002 1007 1006 DOOR PARTS 6 2 EV EV ...
Страница 27: ...2381 2004 2001 2006 W106 2003 2005 2382 CONTROL PANEL PARTS 6 3 EV ...
Страница 29: ...W102 5015 W101 5006 4002 4003 4002 4001 4000 LARCH BOARD PARTS 6 5 EV ...
Страница 31: ...6003 6005 5008 6006 6004 9003 W101 W108 6007 6007 W108 BASE PLATE PARTS 6 7 EV ...
Страница 32: ...W108 5004 5011 9002 W136 9001 SENSOR PARTS 6 8 EV ...
Страница 33: ...P NO 3828W5S3654 February 2004 Printed in Korea ...