5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Abnormal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Normal
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)
Check high vol-
tage transformer
Output is full power
when you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Normal
Check high vol-
tage capacitor.
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Normal
Check high vol-
tage diode.
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
NOTE : • Make sure the wire leads correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Содержание HMB402
Страница 26: ...1005 1381 1000 1004 1002 1007 1006 DOOR PARTS 6 2 EV EV ...
Страница 27: ...2381 2004 2001 2006 W106 2003 2005 2382 CONTROL PANEL PARTS 6 3 EV ...
Страница 29: ...W102 5015 W101 5006 4002 4003 4002 4001 4000 LARCH BOARD PARTS 6 5 EV ...
Страница 31: ...6003 6005 5008 6006 6004 9003 W101 W108 6007 6007 W108 BASE PLATE PARTS 6 7 EV ...
Страница 32: ...W108 5004 5011 9002 W136 9001 SENSOR PARTS 6 8 EV ...
Страница 33: ...P NO 3828W5S3654 February 2004 Printed in Korea ...