Installation instructions
en
37
G20/
G25
G20
G20
G25
G25
G25.3
G30/G31
G30
G30
Gas pressure (mbar)
20/25
20
25
20
25
25
28–30/37
50
37
Nozzle (mm)
1.48
1.48
1.38
1.50
1.45
1.45
1
0.88
0.94
Bypass nozzle (mm)
0.88
0.88
0.88
0.88
0.88
0.88
0.55
0.55
0.55
Max. input power (kW)
4
4
4
4
4
4
4
4
4
Min. input power (kW)
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
Gas flow at 15 °C and
1013 mbar m
3
/h
0.381/
0.443
0.381
0.381
0.443
0.443
0.433
-
-
-
Gas flow at 15 °C and
1013 mbar g/h
-
-
-
-
-
-
291/286
291
291
Nozzle values for the (3.5 kW) wok burner
Note the following information for the gas types that are listed in the table for some burners.
G20/
G25
G20
G20
G25
G25
G25.3
G30/G31
G30
G30
Gas pressure (mbar)
20/25
20
25
20
25
25
28–30/37
50
37
Nozzle (mm)
1.38
1.38
1.30
1.43
1.36
1.36
0.90
0.73
0.85
Bypass nozzle (mm)
0.88
0.88
0.88
0.88
0.88
0.88
0.55
0.55
0.55
Max. input power (kW)
3.5
3.5
3.5
3.5
3.5
3.5
3.3
3.3
3.3
Min. input power (kW)
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
Gas flow at 15 °C and
1013 mbar m
3
/h
0.333/
0.388
0.333
0.333
0.388
0.388
0.379
-
-
-
Gas flow at 15 °C and
1013 mbar g/h
-
-
-
-
-
-
240/236
240
240
Nozzle values for the lower burner in the gas oven with thermostat
Note the following information for the gas types that are listed in the table for some burners.
G20/G25
G20
G20
G25
G25
G25.3
G30
G30
Gas pressure (mbar)
20/25
20
25
20
25
25
28–
30
50
Nozzle (mm)
1.16
1.16
1.10
1.34
1.21
1.21
0.85
0.75
Bypass nozzle (mm)
0.76
0.76
0.67
0.80
0.70
0.70
0.48
0.45
Max. input power (kW)
3
3
3
3
3
3
3
3
Min. input power (kW)
-
-
-
-
-
-
-
-
Gas flow at 15 °C and 1013 mbar m
3
/h
0.285/0.332
0.285
0.285
0.332
0.332
0.325
-
-
Gas flow at 15 °C and 1013 mbar g/h
-
-
-
-
-
-
218
218
Nozzle values for the gas grill burner – gas oven
Note the following information for the gas types that are listed in the table for some burners.
G20/G25
G20
G20
G25
G25
G25.3
G30
G30
Gas pressure (mbar)
20/25
20
25
20
25
25
28–
30
50
Nozzle (mm)
1.00
1.00
0.98
1.13
1.10
1.10
0.70
0.62
Bypass nozzle (mm)
-
-
-
-
-
-
-
-
Max. input power (kW)
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
Min. input power (kW)
-
-
-
-
-
-
-
-
Gas flow at 15 °C and 1013 mbar m
3
/h
0.2/0.233
0.2
0.2
0.233
0.233
0.228
-
-
Gas flow at 15 °C and 1013 mbar g/h
-
-
-
-
-
-
153
153