10
connect electric –
flexible conduit connection
The range can also be connected via flexible conduit.
If using this method, always use the lugs supplied.
Note: In Canada, the range is shipped from the facto-
ry with the range cord already installed. Continue to
“Complete the installation” on page 11.
four wire flexible conduit connection
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. Remove the top nut, star washer, and round
washer from each post.
note: DO NOT remove last round washer, last nut or
internal wire leads.
4. Remove screw from bottom end of ground strap.
5. Remove ground strap from center post. Discard.
6. Attach one terminal lug (packaged with this
manual) through hole below terminal block with
ground screw.
7. Place one terminal lug (packaged with this
manual) on each post. Replace the star washer
and round washer and secure with 20" (50.8 cm)
pounds of torque.
8. Strip 3/8" (9.5 mm) of insulation from the end of
the wire.
3/8 “
9. Insert the insulated grounding wire into the lug
below the terminal block.
10. Insert stripped end of white wire into the center
lug. Secure the clampingscrew.
lug
clamping screw
wire
11. Insert stripped end of red wire into the left lug.
Secure clamping screw.
12. Insert black wire into the right lug. Secure clamp-
ing screw.
13. Tighten each clamping screw with the appropri-
ate torque (see table).
gauge
torque (in./lbs.)
torque (Nm)
6
35
3.95
8
25
2.82
14. Properly secure flexible conduit at knockout on
angle and at supply side junction box. The wiring
is now complete.
red wire
white wire
green
ground
screw
black wire
green ground wire
note: DO NOT plug in range at this time.
three wire flexible conduit connection
The Four Wire Connection is preferred, but where lo-
cal codes and ordinances permit grounding through
neutral and/or conversion to four wire is impracti-
cal, unit may be connected to the power supply via a
three wire connection.
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. Remove the top nut, star washer, and round
washer from each post.
note: DO NOT remove last round washer, last nut or
internal wire leads.