English 15
Optional: Electrical panel can be
mounted in a remote location.
Example: There is a drawer at the bottom of the cabinet, in
front of the downdraft. This may require the electrical panel
to be mounted in an adjacent cabinet. If blower discharge
is down, electrical panel must be relocated.
1. Remove (4) #8-32 hex nuts and electrical panel. Do not
mount with electrical panel slots facing downward.
2. Installation of a remotely located electrical panel may
be completed after connecting the ductwork and install
the blower. Install electrical panel according to local
codes.
INSTALLATION
Based on blower and ducting option
selected, go to the relevent section:
A - Installation using
fl
exible blower
attached to downdraft
B - Installation using
fl
exible or remote
blower - mounted in a remote
location - ducting through front
panel opening
C - Installation using inline or remote
blower - ducting through left, right,
below or rear
A - Installation using
fl
exible blower
attached to downdraft
(Purchase Model DHG602DUC Flexible Blower separately.)
1. Remove hex nuts to remove front panel cover.
2. Determine whether
fl
ex blower will discharge to the left,
right, or down.
3. If blower discharge is down, remove (4) #8-32 hex nuts
and electrical panel.
4. Place blower over studs around front panel opening.
5. Tighten hex nuts to secure blower in place.
BLOWER
SUPPORT
LEGS
(4) BOLTS
6. Remove bolts from
fl
ex blower housing. Attach blower
support legs to
fl
ex blower housing with these (4) bolts.
Do not tighten bolts at this time.