4.3 Aqua
Stop
valve
The valve system consists of two valves in series, which are actuated
electrically parallel, and the filler valve and safety valve. The safety
function may be actuated via the safety level chamber or electrically
via the float in the base pan. The water flow is then stopped
mechanically. An electric solenoid valve which is enclosed by
a housing is attached to the tap. The housing is connected to the base
pan by a leakage water hose (sleeve of the inlet hose). The water inlet
hose, which connects the valve to the water inlet, and the electrical
control line for the solenoid valve are located inside this leakage water
hose.
Technical specifications:
Nominal
voltage
230–240
V
A
= Solenoid
valves
B
= Control
cable
C
= Inlet
hose
D
= Leakage-water
hose
Frequency
50
Hz
Resistance
2
k
Ω
Flow
rate
2.75
l/min
Water
pressure
0.5–10
bar
202_58300000104305_ara_en_b – 02.11.a
Seite 15 von 53