1 690 706 220
2016-09-14
|
Robert Bosch GmbH
Preparation for installation | FWA 4650 | 51
en
1
2
3
4
5
16900020_Re
Fig. 7:
WLAN-Box cable gland
1 Grommet for 3D measurement system LAN cable 1
2 Grommet for 3D measurement system LAN cable 2
3 Grommet for CCD reference system cable
4 Gland for cable assembly to right sensor
5 Gland for cable assembly to left sensor
i
Cable assemblies (2 x) to sensors:
Cable assembly left sensor
Cable assembly right sensor
2 x LAN cable
3D measurement system
2 x LAN cable
3D measurement system
1 x cable
CCD reference system
1 x cable
CCD reference system
Tab. 13: WLAN-Box cable assemblies
5. Route the cable assembly through the cable hole in
the WLAN-Box.
6.
Route the cable assembly through the seal.
7.
Route the cable assembly through the lock nut.
8.
Pull the cable assembly 340 mm into the WLAN-Box.
9.
Open up the grommet.
16900021_Re
1
2
3
4
5
Fig. 8:
WLAN-Box cable penetration
1 3D measurement system LAN cable 1
2 3D measurement system LAN cable 2
3 CCD reference system cable
4 Length of cable assembly pulled in = 340 mm
5 Cable gland components
10.
In front of the cable hole on the outside of the
WLAN-Box housing, place the cable assembly in
3 cable penetrations of the grommet.
11.
Fit a plug in the 4th penetration.
12.
Close the grommet.
13.
Insert the grommet in the housing half with U-clip.
14.
Insert the grommet in the other half of the housing.
15.
Fit and clip together the two halves of the housing.
16.
Guide the thread of the cable gland into the
WLAN-Box cable hole.
17.
Fit the seal in position.
18.
Fit the cable gland with the lock nut.
19.
Proceed in the same manner for the 2nd cable
assembly.
16900022_Re
1
Fig. 9:
Looped cable assembly in WLAN-Box
1 Example of routing of 3D measurement system LAN cables (4 x)
and CCD reference system cables (2 x)
20.
Loop the cable assemblies in the WLAN-Box.
Содержание FWA 4650
Страница 2: ......