44
en | Configuration
FLEXIDOME multi 7000i | FLEXIDOME multi 7000i
IR
2021-04 | 01 |
User manual
Bosch Security Systems B.V.
RCP+ port 1756
Activating RCP+ port 1756 allows unencrypted connections on this port. To allow only
encrypted connections, set the
Off
option to deactivate the port.
Discovery port (0 = Off)
Enter the number of the port that you want to discover.
To deactivate the port, enter 0.
Interface mode ETH
If necessary, select the Ethernet link type for interface ETH. Depending on the device
connected, it may be necessary to select a special operation type.
Network MSS [Byte]
Set the maximum segment size for the IP packet's user data here. This gives the option to
adjust the size of the data packets to the network environment and to optimize data
transmission. In UDP mode, comply with the MTU value set below.
Network MTU [Byte]
Specify a maximum value in bytes for the package size (including IP header) to optimize data
transmission.
Click
Set
to apply the changes.
4.7.3
Advanced
RTSP
RTSP port
If necessary, select a different port for the exchange of the
RTSP
data from the list. The
standard
RTSP port
is 554. Select
Off
to deactivate the
RTSP
function.
802.1x
Authentication
To configure Radius server authentication, connect the unit directly to a computer using a
network cable. If a Radius server controls access rights over the network, select
On
to activate
authentication to communicate with the unit.
Identity
Enter the user name that the Radius server uses for the unit in the
Identity
field.
Password [EAP-MD5]
Enter the
Password [EAP-MD5]
that the Radius server expects from the unit.
Certificates [EAP-TLS]
Shows the client and server certificates.
Click
Configure
to go to the
Certificates
page and manage certificates.
TCP metadata input
TCP port
The device can receive data from an external TCP sender, for example an ATM or POS device,
and store it as metadata. Select the port for TCP communication. Select
Off
to deactivate the
function.
Sender IP address
Enter a valid
Sender IP address
.
Syslog
Server IP address
Enter the appropriate IP address of the server.
Содержание FLEXIDOME multi 7000i
Страница 2: ......
Страница 53: ...FLEXIDOME multi 7000i FLEXIDOME multi 7000i IR Appendices 53 Bosch Security Systems B V User manual 2021 04 01 ...
Страница 54: ...54 Appendices FLEXIDOME multi 7000i FLEXIDOME multi 7000i IR 2021 04 01 User manual Bosch Security Systems B V ...
Страница 55: ......